6.2.
continuous drain
6.2.1.
unscrew the water cap in the direction shown by the arrow and unplug the water plug;(fig 7)
6.2.2.
Attach a drain hose onto the water outlet; (fig 8)
6.2.3.
connect the drain hose to a suitable drainage point.
note:
the drain hose must be installed when there is no water in the baseplate;
6.2.4.
When operating in the cooling mode, to ensure the water for radiation of the condenser of the unit and to enhance the cooling effects
of the unit, it is recommended that continuous drain is not be set when the unit is in use;
6.2.5.
When operating in the heating mode, use continuous drain; otherwise, the unit may shut down due to water level becoming full. Place
the drain hose at a height that is not above the water outlet.
6.2.6.
Prevent the drain hose from becoming kinked.
6.2.7.
When continuous drain is in use, keep the drain cap and water plug closed.
7. maintenance & ServicinG
note:
disconnect from the mains before carrying out any servicing or maintenance.
7.1.
clean the surface of the unit with wet soft cloth. do not use chemical solvents as these may damage the unit.
7.2.
filter frame and filter mesh cleaning
7.2.1.
Clean the filter mesh once every two weeks.
7.2.2.
If the filter frame and filter mesh are clogged with dust, the function of the air-conditioner may decrease.
7.2.3.
Remove the evaporator filter frame and the condenser filter frame gently in the direction shown by the arrow (as shown in Fig 9).
7.2.4.
Remove the evaporator filter mesh and condenser filter mesh gently in the direction shown by the arrow (a
s shown in fig 10).
7.2.5.
Remove the filter frame first and then take out the filter mesh.
note:
when taking out the
filter frame or filter mesh, the force shall be applied evenly to avoid twisting or damage of the filter frame or
filter mesh.
7.2.6.
Place the evaporator filter frame, condenser filter frame, evaporator filter mesh, and condenser filter mesh into warm water (about
40°c). use neutral cleaner. dry in the shade. (fig 11)
note:
Do not damage the mesh fabric on the filter frame and filter mesh.
7.3.
Installation of the filter frame and filter mesh
7.2.7.
Install the filter mesh first and then install the filter frame.
7.2.8.
To install the evaporator filter mesh and condenser filter mesh, point the back end of the filter mesh toward the socket and then push
the filter mesh evenly and gently into the socket.
note:
Install the filter mesh in the reverse order of removal. The filter mesh must be installed into place; otherwise, the filter frame may
not be installed into place.
fig.8
fig.7
fig.11
fig.9
fig.10
s
AC9001 | Issue 3 (L) 29/11/16
Original Language Version
© Jack sealey limited
fig.12