UPGRADING FIRMWARE VIA COMMAND PROMPT PROCEDURE

 

To execute IOCU.exe from a command prompt, Click on Start, then click Run and type “cmd” (without the 
quotation marks) and hit ENTER.  You will then see a command prompt (i.e. c:\documents and 
settings\name>). Once you are at the command prompt, browse to your SeaMAX folder. The default 
location is “C:\Program Files\Sealevel Systems\SeaMAX\” (or “C:\Program Files (x86)\Sealevel 
Systems\SeaMAX” on 64-bit systems). Your *.hex file should be saved to this folder as well. If your 
operating system requires administrator permissions for this action and you cannot provide them, another 
folder outside the Program Files folder can be used, but a full path to the file will be required in the following 
step. 

Type 

Cd “C:\Program Files\Sealevel Systems\SeaMAX\”   and then press Enter 

When the command calls for iii.iii.iii.iii you substitute the unit’s IP address. Please do not enter the numbers 
with a leading zero. Therefore, if your IP address is 192.168.42.11, you will enter 192.168.42.11 and not 
192.168.042.011.  The command for this is therefore: 

iocu /i=192.168.42.11 /a=247 120.hex 

Once the unit has received the download request it will turn on the ACT light. Once the download starts, the 
ACT light will flash rapidly as data is downloaded. Once the download is complete, the ACT light will remain 
on while the device is reprogramming itself. The unit will then reboot itself to reload the new firmware. At 
this point, the ACT light will turn off. 

 

 

 

Summary of Contents for eI/O 110E

Page 1: ...1 Sealevel Systems Inc eI O Manual SL9221 01 2023 eI O Modules User Manual eI O...

Page 2: ...ORE YOU GET STARTED 3 INTRODUCTION 4 EI O HARDWARE DESCRIPTION 9 POWER OPTIONS 21 SEAMAX APPLICATION SUITE 22 HARDWARE CONFIGURATION 31 MOUNTING OPTIONS 39 APPENDIX A HANDLING INSTRUCTIONS 40 APPENDIX...

Page 3: ...d result to the product or the user could suffer serious injury Important The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the p...

Page 4: ...library or industry standard Modbus TCP Ethernet protocol Industry Segments eI O modules are perfect for a wide variety of applications and environments including Process Control Data Acquisition Bro...

Page 5: ...orm C Relay Outputs eI O 160E 32 Channel TTL Interface eI O 170E 8 Analog Inputs 2 Optically Isolated Inputs 2 Solid State Relay Outputs Power Over Ethernet eI O 110PoE 4 Optically Isolated Inputs 4 F...

Page 6: ...O modules without power cables with the Sealevel unmanaged five port Ethernet switch POWER SUPPLIES US OPTIONS eI O 120VAC to 12VDC 500mA Wall Mount Power Supply Part TR104 The TR104 is a wall wart st...

Page 7: ...ERNATIONAL OPTIONS eI O 230VAC to 12VDC 500mA Wall Mount Power Supply Part TR105 The TR105 is a wall wart style power supply for European countries and is rated for 230VAC input and 12VDC output at 50...

Page 8: ...Manual SL9221 01 2023 CABLES CAT5 Patch Cable Part CA246 Standard 7 CAT5 UTP Patch Cable RJ45 CAT5 Patch Cable 10 in Length Part CA247 10 Blue Ethernet Patch Cable Can be used to connect eI O Ethernet...

Page 9: ...SL9221 01 2023 eI O Hardware Description eI O Standard and Power over Ethernet Modules eI O modules are powered in one of two ways 9 30 VDC 5W MAX power input 600mA MAX 9V 420mA MAX 12V 210mA MAX 24V...

Page 10: ...l models use the same style of 3 5mm pitch screw terminals on front for connection to field devices Status LEDs are also included on the front of all eI O modules to indicate the following information...

Page 11: ...d via 3 5mm field removable terminal blocks Do not connect protective earthing or protective bonding conductor wiring of any equipment to relay contact outputs Minimum hardware requirements Inputs Typ...

Page 12: ...connections Each pair of inputs shares a common and field wiring is simplified via 3 5mm field removable terminal blocks Do not connect protective earthing or protective bonding conductor wiring of an...

Page 13: ...th 2500VAC RMS 3500VDC external isolation and high channel to channel isolation Each pair of inputs shares a common and field wiring is simplified via 3 5mm field removable terminal blocks Inputs Type...

Page 14: ...removable terminal blocks Do not connect protective earthing or protective bonding conductor wiring of any equipment to relay contact outputs Minimum hardware requirements Outputs Type 4 SPST Form A R...

Page 15: ...nd includes normally open and normally closed contact connections Field wiring is simplified via 3 5mm field removable terminal blocks Do not connect protective earthing or protective bonding conducto...

Page 16: ...ic for inputs and outputs The eI O 160 addresses the 32 channels of buffered drive digital I O as four eight bit ports Each port is programmable as input or output The I O channels are accessed via an...

Page 17: ...y rack to determine how this jumper can be disconnected 50 PIN HEADER CONNECTOR The eI O 160 has the following pin out which is compatible with a wide variety of industry standard solid state relay ra...

Page 18: ...18 Sealevel Systems Inc eI O Manual SL9221 01 2023...

Page 19: ...0 10V 5V to 5V and 10V to 10V to provide optimal accuracy depending on application Digital inputs are pre biased internally and current limited so a connection to ground is all that is necessary to ac...

Page 20: ...ting the input The inputs were designed this way so the end user does not need to provide a voltage source A simple external contact closure is all that is required to trigger the input Two common pin...

Page 21: ...des In particular DC supply wiring must include overcurrent protection which limits the maximum fault current to 8A The eI O PoE units are Class 0 IEEE 802 3af 2003 Power over Ethernet devices This al...

Page 22: ...log I O modules supported by SeaMAX software are designed to work with third party applications via the SeaMAX API To help simplify application development the complete API documentation and code samp...

Page 23: ...downloaded if you are using Windows 7 or newer operating systems right click on the installer executable and choose Run as Administrator If you are using an operating system prior to Windows 7 double...

Page 24: ...n tested with Windows 2000 XP Vista and Windows 7 HOST PC CONFIGURATION TAB When you run the MaxSSD utility Start All Programs Sealevel Systems SeaMAX MaxSSD Configuration Utility it will default to t...

Page 25: ...ion or proceed to the Troubleshooting section at the end of this manual SEAI O CONFIGURATION TAB Once the host computer is configured correctly the SeaI O Configuration tab becomes available Before co...

Page 26: ...rmware version number interface and I O type In the example shown the module found at slave ID 1 is an eI O 170 module with a PoE Modbus TCP interface After a successful Get operation additional tabs...

Page 27: ...anner When banks of inputs are displayed the status LEDs update on each of the banks automatically This allows you to actively monitor external signals With a bank of outputs the output coils can be s...

Page 28: ...s they are automatically saved to the device as you select the various configuration options Show Hexadecimal Values checkbox Displays the values returned by the A D converter as a hexadecimal value w...

Page 29: ...vs patch cables 4 Use the MaxSSD utility included in the SeaMAX software suite to verify proper installation MaxSSD is designed to simplify the installation configuration and diagnostics of Sealevel...

Page 30: ...ngs that would hinder UDP transmissions are disabled It is also possible that the eI O module may not be discovered if the PC and module are on separate subnets This may occur if the module s IP addre...

Page 31: ...4 the last octet can be anything but 253 Start the Ethernet Config utility Start All Programs Sealevel Systems SeaMAX Ethernet Configuration Tool installed with SeaMAX Click on the Search for SeaI O D...

Page 32: ...s to communicate with the eI O module Ensure a successful Get operation refer to the MaxSSD section of this manual for more information RESETTING AN ETHERNET eI O MODULE An eI O module may become no l...

Page 33: ...address reconfigure the card to another IP address before you proceed Once the card is reconfigured click Cancel in the reset window and click Recover Module again You can now select the card s new I...

Page 34: ...mmand FUNC_SEAMAX_GET_EXTENDED_INFO 0x66 using the SeaMAX method SM_GetDeviceConfig or by viewing the Module Description in MaxSSD shown below FIRMWARE UPGRADING In the event that a newer version of t...

Page 35: ...is firmware upgrade will be a file with a name similar to your eI O model number with an extension of hex As an example it you have an eI O 120 style module the programming file name would be 120 hex...

Page 36: ...ing run in a terminal window Once the unit has received the download request it will turn on the ACT light Once the download starts the ACT light will flash rapidly as data is downloaded Once the down...

Page 37: ...er folder outside the Program Files folder can be used but a full path to the file will be required in the following step Type Cd C Program Files Sealevel Systems SeaMAX and then press Enter When the...

Page 38: ...and data Mode A Power over Ethernet 802 3af 2003 configurations are acceptable for the eI O The eI O PoE series modules are class 0 power over Ethernet devices ETHERNET POE CONNECTOR RJ 45 Pin Signal...

Page 39: ...nection method Wall Panel Mounting As an alternative to DIN rail the versatile plastic clip includes mounting holes that allow eI O modules to be mounted to walls under counters or inside panels The p...

Page 40: ...s in their containers until they arrive at an electrostatically protected workplace Only touch electrostatically sensitive components when you are properly grounded Store electrostatically sensitive c...

Page 41: ...tion can be found at http www sealevel com faq asp Sealevel Systems maintains a web page on the Internet Our home page address is www sealevel com The latest software updates and newest manuals are av...

Page 42: ...standards must be met EN55022 Class A Limits and methods of measurement of radio interference characteristics of information technology equipment EN55024 Information technology equipment Immunity cha...

Page 43: ...nty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prep...

Reviews: