Page 1: ...LEPUS BOX 120V 24V REV 03 10 2020 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Toll Free 800 689 4716 www sea usa com 67411870 ...

Page 2: ...hildren to play or stay within the path of the moving gate 9 Keep remote control or any other control devices out of the reach of children in order to avoid possible involuntary activation of the gate operator 10 In case of break down or malfunctioning of the product disconnect from the main power source Do not attempt to repair or intervene directly contact only qualified personnel for repair 11 ...

Page 3: ...ator Instructions regarding intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent shall be supplied where applicable IMPORTANT INSTALLATION INSTRUCTIONS a Install the gate operator only when 1 The operator is appropriate for the construction of the gate and the usage Class of the ...

Page 4: ...all provide warning notices on not assessable further risks SEA USA Inc in its relentless aim to improve the products is allowed to make whatsoever adjustment without giving notice This doesn t oblige SEA to up grade the past production SEA USA Inc can not be deemed responsible for any damage or accident caused by product breaking being damages or accidents due to a failure to comply with the inst...

Page 5: ... objact closer than 16 inches 406mm are not required to be provided with a means of entrapment protection B1 and B2 means of entrapment protection MUST be MONITORED HORIZONTAL SLIDE VERTICAL LIFT VERTICAL PIVOT ENTRAPMENT PROTECTION TYPES TYPE A TYPE B1 TYPE B2 TYPE C Inherent entrapment protection system Non contact sensors such as photoelectric sensors or equivalents Contact sensors such as edge...

Page 6: ...ment fig 11 GATEARRANGEMENT The first thing to check is that the gate is in good running order as follows a The gate is rigid and straight and runs smoothly throughout its travel b That the inferior sliding guide rail is perfectly straight and horizontal to avoid a derailment of the gate fig 1 furthermore it must be free of irregularities and foreign bodies which could obstruct the normal run of t...

Page 7: ...ower supply CAUTION Operatormustbestartedonlyafterhavingcorrectlyinstalledandadjustedall components WARNING It is mandatory to switch off the power supply by putting switch to OFF when you need to work on the operator eg repairs power loss components installation Into LEPUS BOX you can also find two useful power sockets Fig 13 which allow to connect work tools or accessories for a maximum total lo...

Page 8: ... the gate from derailment Fig 16 4 TYPE OF INSTALLATION 3 TYPICAL INSTALLATION 1 Operator 2 Concrete to build operator on 3 Photocells 4 Safety edge 5 Key switch 6 Travel gate stops 7 Radio receiver 8 Guide rollers 9 High speed ball bearing wheels 10 Warning notice inside 11 Warning notice outside Fig 16 WARNING Only for vehicles access pedestrians MUST have separate entrance Install the operator ...

Page 9: ...ng through the openings anywhere in the gate and in that portion of the adjacent fence that the gate covers in open position 5 5 Follow the local building code to determine the required depth of the concrete pad 5 6 SEArecommend the following pad measurements 5 CONCRETE PADS 6 GATE OPERATOR ATTACHMENT 6 1 Before starting the installation of the gate operator make sure that the gate the support whe...

Page 10: ... notice the obliged run of the chain inside the pinion group which must not be modified For a correct installation follow carefully the indications below 7 1 Fix the angle irons with screws not supplied to the two extremities of the gate and fix the chain with the provided tie rod Fig 24 Open position Closed position 7 CHAIN INSTALLATION ...

Page 11: ...r completely released using the provided special release key 7 2 Install the chain making it pass through the pinion group as in Fig 26 The chain must be always in line both vertically and orizontally if not perfectly aligned Fig 27 and Fig 28 it may derail from the pinion group or the motor reducer risks a greater effort not allowing the right operating of the system ...

Page 12: ...ct on the clutch with an hexagonal key 8 3 Act on the A screw Fig 31 in the following way Clockwise less clutch sensibility and more pushing force Anti clockwise more clutch sensibility and less pushing force 8 CLUTCH ADJUSTMENT Fig 31 A FORCE FORCE 9 EXTERNAL RELEASE INSTALLATION Fig 32 Security box ...

Page 13: ...g 44 Fig 41 Fig 40 LEFT MOUNTING RIGHT MOUNTING Note The antenna must be connected on the clamps 1 and 2 of the control unit CN1 connector For further information on the antenna wiring diagram please refer to the control unit user s manual ...

Page 14: ... its half run Fig 36 and that the gate is in its half run too To set or adjust the limit switch act only on the external screw Do not open the limit switch casing 11 4 To install and adjust the limit switches in opening release the operator open the gate manually act on the adjusting screw so that the microswitch can activate the contact with the cursor Fig 37 11 5 To install and adjust the limit ...

Page 15: ...auge 8 Gauge 4 Gauge Up to 150 FT 250 FT 400 FT 650 FT 1000 FT 2200 FT Up to 75 FT 125 FT 200 FT 325 FT 500 FT 1100 FT N Neutral G Ground P Single Phase 120 V ON OFF switch 120V POWER WIRE HP and DUAL MOTOR 1 HP Fig 45 Sockets W H I T E GREEN BLACK BLAC K WH ITE GREEN N G P ...

Page 16: ...uarantee will be void and the manufacturer responsability will be nullified if SEA USA Inc original spare parts are not being used The electrical installation shall be carried out by a professional technician who will release documentation as requested by the laws in force Packaging materials such as plastic bags foam polystyrene etc must be kept out of children s reach as dangers may arise WARNIN...

Page 17: ...ll be refused Customers must contact SEAfor instructions WARRANTY for the original buyer only Hydraulic and oil bath motors 36 months warranty from the date of invoice on manufacturing assembling and workmanship defects Electro mechanic motors and electronic control systems 24 months warranty from the date of invoice on manufacturing assembling and workmanship defects Lepus and Full Tank Standard ...

Page 18: ...NOTES ...

Page 19: ......

Page 20: ...SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Toll Free 800 689 4716 www sea usa com sales sea usa com ...