background image

SPOT 3

User's Guide

By SDX Business Systems Limited

38GDE00001SCA - Issue 2

Summary of Contents for SPOT 3

Page 1: ...SPOT 3 User s Guide By SDX Business Systems Limited 38GDE00001SCA Issue 2...

Page 2: ......

Page 3: ...lume 11 Working with PC Applications 12 General Application Notes 12 Windows Cardfile 13 Windows Terminal 15 Using SPOT as an Answering Machine 15 Appendix A SPOT Commands 17 Introduction 17 Hayes AT...

Page 4: ......

Page 5: ...ations provided on the SPOT software disk include their own help files to guide you This chapter outlines the main features of SPOT The other chapters are Installing SPOT This is the place to start Us...

Page 6: ...you can dial calls automatically from your PC applications send and receive faxes use voicemail and answering machine software and access on line information services All this functionality is provide...

Page 7: ...tion mute and volume controls and redial SPOT can operate as a normal handsfree telephone without the PC lead being connected Telephone Specification On hook dialling Handsfree speech Last number redi...

Page 8: ...tween SPOT and the PC Modem Specification Hayes AT compatible 1200 or 2400 bits per second BABT approved Compatible with V21 V22 V22bis RS232C serial lead 9 PIN D type connec tor Power from DC power s...

Page 9: ...er supply unit with lead 9 pin to 25 pin serial connector adapter Manual s see note Software disk s You also require BT jack socket PC with free 9 pin or 25 pin D type serial port see below PC Require...

Page 10: ...e socket 5 Plug the SPOT power supply unit into a mains supply socket and switch on 6 Plug the power supply cable into the socket under the SPOT phone 7 Test the connection by making a normal phone ca...

Page 11: ...tions in Connecting SPOT to a Telephone Socket on page 6 2 Plug the SPOT power supply unit into a suitable mains supply socket and switch on 3 Plug the power supply cable into the socket under the SPO...

Page 12: ...From the menu bar select File and then Run 4 Enter a install exe or b install exe and then click on OK 5 Follow the on screen instructions 6 When the SPOT Registration screen appears go to Registerin...

Page 13: ...e busy or you chose not to register you can run registration at a later date Registering your SPOT 1 Enter information for any items highlighted in b lue 2 The SPOT serial number is located on the lab...

Page 14: ...setup SPOT dialling ringer controls 1 Without picking up the handset press SETUP Whilst the lamp flashes for approximately four seconds select one of the following options To set LD dialling press 1 T...

Page 15: ...ou can switch between handsfree and handset use a call To switch from the handset to handsfree 1 Press SPEAKER and replace the handset To switch from handsfree to the handset 1 During the call simply...

Page 16: ...ther set the AT Dial prefix to ATDTV or put a V at the beginning of all telephone numbers Most Hayes AT autodialling applications expect to control a modem that shares a socket with a phone Thus they...

Page 17: ...s or business contacts Cardfile Setup Before dialling numbers from Cardfile you must tell it about SPOT Cardfile saves the settings for all future calls To setup Cardfile for SPOT 1 Start Cardfile and...

Page 18: ...ber to dial 2 Press F5 or click on Card and then Autodial 3 If necessary change the number and optional prefix 4 At this point you can click on Setup to view and change the SPOT setup if necessary see...

Page 19: ...etup Terminal supports multiple setups which you can save as files and then load when required The setup may vary according to the service being accessed at the other end To setup Terminal for SPOT 1...

Page 20: ...e Answering Machine software you use However we advise that when recording your announcement it should start within 3 seconds it should contain your full telephone number and it should invite the call...

Page 21: ...standard for PC applications to control modems See Hayes AT Commands on page 18 Hayes ATV Commands Normally modems are used for the interchange of signals between computers The AT command set has bee...

Page 22: ...ode after dialling X Extended results selection S0 DSR always active X0 Blind dialling S1 DSR active at connection E Echo select X1 As X0 plus connect speed T Test Commands E0 Disabled X3 As X1 plus b...

Page 23: ...T S Register Values Limits Units Default Description S0 0 6 rings 0 Automatic answer control S1 0 255 rings 0 Ring counter S2 0 255 ASCII 43 Escape code character S3 0 127 ASCII 13 Carriage return cha...

Page 24: ...arrier signal detected or signal lost or no connection 4 ERROR Invalid command issued or error in command 5 CONNECT 1200 Connection between DTE and SPOT established at 1200 bps 6 NO DIALTONE No dialto...

Page 25: ...ain in the range 6 2dB to 20 8dB default 119 6 4dB The default should not be set above 130 in order to comply with BABT regulatory requirements H n Voice relay activation H 0 Telephone dialling mode H...

Page 26: ...ure key press events 000 DTMF dial Disable auto dial 049 Dial F1 Setup 002 DTMF dial Enable auto dial 050 Dial F2 Redial 004 LD dial Disable auto dial 051 Dial F3 Mute 006 LD dial Enable auto dial 052...

Page 27: ...l 48 Dial DTMF 0 77 Bell on set up 16 Release line interface 49 Dial DTMF 1 Line mute 17 Seize line in handset mode 50 Dial DTMF 2 80 Unmute line interface 18 Seize line in handsfree mode 51 Dial DTMF...

Page 28: ...DTR Data Terminal Ready 4 20 Signal ground 5 7 DSR Data Set Ready 6 6 RTS Ready To Signal 7 4 CTS Clear To Signal 8 5 RI Ring Indicator Not used 9 22 Telephone Cable The SPOT line cord is terminated...

Page 29: ...n this manual Other usage will invalidate any approval given to this apparatus if as a result it ceases to comply with EN60950 EN41003 Interconnection directly or by way of other apparatus of ports ma...

Page 30: ...n 3 1 defines three modes Mode 1 Mode 2 and Mode 3 Mode 3 covers devices which auto dial the BT emergency service 999 or 112 and then play a recorded message e g burglar fire alarms Mode 2 covers devi...

Page 31: ...a REN of 1 one unless otherwise marked and all other equipment should be clearly marked with an appropriate REN value Because of the ringing detector characteristics a guarantee of successful operatio...

Page 32: ...F tone dialling 7 Simple telephony Any other usage will invalidate the approval of the apparatus if as a result it then ceases to conform to the standards against which it was approved SPOT is only ap...

Page 33: ...industry standard Hayes commands are supported by a wide range of modems and software packages HAYES AT A Hayes ATtention command from a PC to a modem The AT is followed by the command which consist...

Page 34: ...SPOT 3 User s Guide TBR Time break recall A method used to signal to the exchange Most MF phones support several method of recall and have a switch on their base to select the mode required SPOT uses...

Page 35: ...11 Handsfree switching 11 Hangup prefix 12 Hangup suffix 12 Hayes 17 Hayes compatibility 4 L LD 10 M MF 10 Modem Settings 12 Specification 4 Mute 11 P Parity 12 Parts 5 Phone Specification 3 Power re...

Page 36: ...below Please note that this is a registration assistance number only and telephone support will not be provided on this line Product Registration Assistance 01923 208439 Warranty SDX Business Systems...

Reviews: