HotFind-D Infrared Camera Operation Manual
19
camera, the temperature can be revised. In the normal condition, it
is “0
℃
”.
(5).Isotherm width
This is to set the width of the isotherm range. It can be set from 0.1
℃
to the upper limit. The standard upper limit is 330
℃
.
(6). Isotherm color
The color of isotherm can be displayed in red or green.
(7).Isotherm alarm
It offers the selection from 1 to 255. 1 is the most sensitive whereas
255 is the least.
(8).Laser Adjust
It offers the re-selection to define the position of laser point and
measure spot. When it’s on, user can readjust the laser point
direction to correspond with the measuring spot 1. When it’s off,
the position of laser point will be recorded. More details in Chapter
5.7.
2. Local Setup
Select this and press the menu(enter) key that there will be a
box display in the screen as below. Use the direction key to change the
setting.
(
1
)
Language
Chinese, English, French, German, Italian, Spanish and
Summary of Contents for HotFind-D