HotFind-D Infrared Camera Operation Manual
18
comes out in the screen as below, use the direction keys to change
the parameters and fulfill the different analysis.
(1).Capture Spot
This is to setting the “highest spot/lowest spot” of the “analysis”
menu. If the highest spot was selected, the camera will auto-track
the highest temperature of the area and display the temperature
value; if the lowest spot is selected, the camera will auto-tracking the
lowest temperature of the area and display the temperature value.
(2).Temperature alarm
This is for turning on or turning off the temperature alarm
function. When turning on this function, if the temperature of “highest
spot” is higher than the preset alarm temperature, the value will
display in red and the camera will buzz itself; if the temperature of
“lowest spot” is lower than the preset alarm temperature, the value
will display in red and the camera will buzz itself.
(3).Alarm Temperature
This is to preset the alarm temperature value.
(4).Revised temperature
In some special condition, in order to assure the accuracy of the