8.   MAINTENANCE AND UPKEEP

8.1 Failure information and code

In case the unit runs under abnormal condition, failure 
protection code will display on both control panel and wired 
controller, and the indicator on the wired controller will flash 
with 1Hz. The display codes are shown in the following table: 

Table 8-1

No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

Code

Reason

EEPROM error of main control board 

EEPROM error of inverter module A

EEPROM error of inverter module B

Total water outlet temperature sensor error(master only)

Outlet water temp sensor error 

Condenser tube temperature sensor error 

System self check fault alarm

Discharge pipe temperature sensor error alarm

Total cooling outlet temperature sensor(Tz) error

High pressure or air discharge temperature protection
(protection occurs for 5 times in 120 minutes and the 
failure can be recovered by power disconnection only)

Low pressure protection(protection occurs for 5 times in 120 minutes 
and the failure can be recovered by power disconnection only)

System A Current protection(protection occurs for 5 times 
in 120 minutes and the failure can be recovered by power 
disconnection only)

System B Current protection (protection occurs for 5 times
 in 120 minutes and the failure can be recovered by power
 disconnection only) 

Protection of outlet and inlet water temperature difference(protection
 occurs for 3 times in 60 minutes and the failure can be recovered by 
power 

System self- check error alarm

Outdoor ambient temperature sensor error

Outdoor ambient temperature sensor error

Inlet water temperature sensor error

Evaporator anti-freezing temperature sensor (T62)error

Communication error between main control board and wired controller

Power phase sequence error

P1

P0

1E0

E1

E2

E3

E4

E5

E7

E8

E9

1Eb

1Ed

2Ed

1P6

2P6

EC

EF

EH

EP

EU

2E0

3E0

P4

P5

P9

Condenser high temperature protection 

Inlet water high temperature in cooling mode

System anti-freezing protection

PA

Pb

System B discharge pipe temperature sensor error

P7

System A inverter module protection

System A discharge pipe temperature sensor error

System A inverter module protection

Outdoor ambient temperature sensor error

Tfin module high temperature protection(Protection occurs for 
3 times in 100 minutes and the failure can be recovered by 
power disconnection only)

DC fan A module protection

DC fan B module protection

PL

33

32

31

28

29

30

34

35

36

37

38

39

40

41

42

43

44

45

46

47

System A IPM module Communication error

System B IPM module Communication error

Under/Over voltage protection

System A  DC bus voltage error

System B  DC bus voltage error

Pressure sensor error

DC bus low voltage protection

DC bus high voltage protection

MCE error

Zero speed protection

Phase sequence error

DC fan A error

Air suction temperature protection error

Heat recovery temperature sensor error

Inverter module protection

Three times 2PP protection within one hour (power off recovery)

Three times 1PP protection within one hour (power off recovery)

L7

Compressor frequency variation greater than 15Hz 
within one second protection

L8

Actual compressor frequency differs from target 
frequency by more than 15Hz protection

L9

Defrosting prompt 

dF

1H0

2H0

H1

1H4

2H4

1H6

2H6

Fb

Fd

FE

1FF

2FF

FP

L0

L1

L2

L4

L5

1PU

2PU

DIP inconsistency of multiple water pumps(Power 
failure recovery required)

DC fan B error

25

26

27

Evaporator pressure low in cooling mode

PC

Low-temperature protection of evaporator (manual recovery)

PE

T4 high temperature protection in heating mode

PH

Summary of Contents for SCV-xxEA

Page 1: ...AIR COOLED MODULAR CHILLER UNIT INSTALLATION AND USER MANUAL SCV xxEA AIR CONDITIONING...

Page 2: ...Original instructions...

Page 3: ...A Temperature testing components of total water outlet 1 1 1 1 Purpose Shape Qty Unit transformer Installation Operation Manual Use for installation only need for setting the main module Installation...

Page 4: ...2 SCV 600EA NO NAME 1 2 3 4 5 6 7 Air outlet Top cover Air inlet Electric control box Condenser Compressor Evaporator NO NAME 8 9 Water outlet Water intlet 1 2 8 7 9 4 6 3 5...

Page 5: ...matching and thus actually realizing optimal energy saving operation The product is Modularized unit and parallel connection of 16 modules can be realized at most so the user can adopt module combina...

Page 6: ...as unsorted municipal waste Collection of such waste separately for special treatment is necessary Keep far away from high frequency equipment Keep away from the following places a place where it is f...

Page 7: ...ticide Failure to observe could cause the chemicals to become deposited in the unit which could endanger the health of those who are hypersensitive to chemicals Do not place appliances which produce o...

Page 8: ...tend below frozen soil layer The foundation of the unit should not be connected to the foundation of the building to avoid affecting the people due to transfer of noise and vibration The base of the u...

Page 9: ...han the static pressure outside the fan The space between the unit and sunk fence or Persian blinds should also meet the requirement of the minimum installation space of the unit 3 3 1 3 If the unit n...

Page 10: ...n foundation of the unit unit mm 80 Cement mortar Concrete Drainage channel Fig 3 6 3 6 Installation of damping devices 3 6 1 Damping devices must be provided between the unit and its foundation By me...

Page 11: ...pes a All chilled water pipelines should be thoroughly flushed to be free of any impurity before the unit is operated Any impurity should not be flushed to or into the heat exchanger b Water must ente...

Page 12: ...eck valve Automatic discharge valve Symbol explanation Fig 4 1 Main unit Expansion tank Water replenishing Dirt discharge valve Differential pressure by pass valve Drain valve Two way valve Three way...

Page 13: ...tance pipe elbow and three way resistance two way resistance or three way resistance as well as filter resistance H4 the longest terminal resistance 4 7 2 Installation the pump a The pump should be in...

Page 14: ...ne must be consistent with the direction of arrow on the controller The connection terminal should be located where wiring connectioncan be easily done 4 9 4 Pay attention to the following items when...

Page 15: ...ngle module water system pipeline Fig 4 5 SCV 300EA Fig 4 6 SCV 600EA Water inlet Water outlet Total water outlet temperature sensor Electric control box Electric control box Water inlet Water outlet...

Page 16: ...items are determined The wired controller is 500m away from the outdoor unit 25 Q 50 50 Q 80 80 Q 130 135 Q 210 210 Q 325 325 Q 510 510 Q 740 740 Q 960 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 4 11...

Page 17: ...electromagnetic interference thus leading to failure of the unit and its controller and even damages to them 5 3 10 All weak current wires led to the electric box must apply shielded wires which must...

Page 18: ...d N Step 7 Phase sequences must be consistent when the wires of the main power Step 8 The main power should be located out of easy reach of non professional maintenance personnel to avoid mal operatio...

Page 19: ...hen the subordinate unit suffer fault of temperature sensor the unit will be shut down but other subordinate units will not be affected Taf1 Shell and tube low temperature ant freeze sensor1 fault cod...

Page 20: ...l modules stop operating 3 In case of shutdown under the pump mode the pump can be directly shut down CN30 Input of three phase four wire power supply fault code E1 Three phases A B and C of power sup...

Page 21: ...for the main unit Spot check The operating status of outdoor system can be observed through spot check and specific display contents are as shown in the following figure Display contents of operating...

Page 22: ...ed in Table 7 1 6 2 Check item table after installation Checking item Description Yes No Whether installing site is meet for requirements Whether water system is meeting for requirements Whether elect...

Page 23: ...ler must be connected according to electric control schematic diagram or the faults caused by water breaking while the unit is in operation should be the user s responsibility Do not re start the unit...

Page 24: ...ons 1 Plug and play system 2 RS 485 TS232 Standard serial communication port Turn on the unit Press MENU key to set the intended mode Power up to module unit and initially deliver power to wired contr...

Page 25: ...ir suction pressure Check ambient temperature around it Discharge the excessive refrigerant Charge sufficient refrigerant to the system Check fan rotating direction Reason about remove air short circu...

Page 26: ...re Replace a new compressor Replace damaged assembly Control circuit without power though Check the wring of control system Hi voltage or lo voltage protection Reference to mention in above the parts...

Page 27: ...2 error Communication error between main control board and wired controller Power phase sequence error P1 P0 1E0 E1 E2 E3 E4 E5 E7 E8 E9 1Eb 1Ed 2Ed 1P6 2P6 EC EF EH EP EU 2E0 3E0 P4 P5 P9 Condenser h...

Page 28: ...ll be a dynamic display of If the system is under OFF state there is no display c If the communication with the main unit Modular unit is fail it displays E2 d If it is under the host computer network...

Page 29: ...d check suction and discharge pressure Maintenance of main parts Close attention should be paid to the discharge and suction pressure during the running process Find out reasons and eliminate the fail...

Page 30: ...el connect the HEAT COOL port of the main unit s electric control box then connect the ON OFF signal provide by user to the HEAT COOL port of main unit as follows 0 electric control box ON OFF port ON...

Page 31: ...temperature of chilled water or hot water Inlet Outlet 6 check air temperature of air side heat exchanger Inlet Outlet 7 Check refrigerant suction temperature and superheating temperature Refrigerant...

Page 32: ...Outdoor temperature Compressor Air temperature of air side heat exchanger Temperature of chilled water or hot water Current of cooling water pump or hot water pump Dry bulb Wet bulb Indoor temperatur...

Page 33: ...etc High or low pressure switch freeze proof device water flow volume controller Overcurrent device power phase sequence device etc Standard heating input kW Heating rated current Notes the above dat...

Page 34: ...to water heat pump Brine to water heat pump For low temperature heat pumps parameters shall be declared for low temperature application Otherwise parameters shall be declared for medium temperature a...

Page 35: ...Kingdom 1 For heat pump space heaters and heat pump combination heaters the rated heat output Prated is equal to the design load for heating Pdesignh and the rated heat output of a supplementary heat...

Page 36: ...iary heater and pump is just for reference please follow the instructions of corresponding auxiliary heater products Please choose such accessory as power wire switch of auxiliary heater according to...

Page 37: ...iliary heater and pump is just for reference please follow the instructions of corresponding auxiliary heater products Please choose such accessory as power wire switch of auxiliary heater according t...

Page 38: ...unit is containing fluorinated gases included in the Kyoto protocol The maintenance and the liquidation must be carried out by qualified personnel Type of refrigerant R410A The composition of the cool...

Reviews: