9
2. SpecificationS
this appliance and flue were tested at the following clearances.
the axis i1000 double free standing appliance and flo-met universal 8” flue system with a painted
solid casing between the appliance and ceiling conforming to joint australian/new Zealand Standards
2918:2001, appendix B.
a minimum 1605mm deep X 1220mm wide and 9mm non-combustible hearth should be used under
the appliance and in front of each appliance door when installing the appliance (see joint aS/nZs
2918:2001 3.3.2). the floor protector should extend 550mm in front of the front both appliance fuel
loading doors and be placed centrally in the 1220mm width.
clearances & Hearth- axis i1000 dS double Sided
CoMbustiblE Walls
hEarth
Co
M
bust
ibl
E W
alls
Cl
Earan
CE
aPPlianCE
1300
MM
550
MM
550
MM
1220MM
sWing Door
sWing Door
1605
MM
450MM
Position a ParallEl Position
diagram not to scale
***the appliance must be elevated a minimum of 250mm above the hearth(on a non combustible
surface). if the heater is placed directly onto the hearth, the hearth dimensions required will be greater.
please refer to aS/nZS 2918:2001 as per the minimum for a non-tested appliance.