5. Taking care of Galileo
72
5. Taking care of Galileo
Procedure:
To replace the battery you need a coin or
the dedicated tool that came with Galileo
and a clean cloth.
!
WARNING
- A leaking battery cap may lead to the
destruction of Galileo by water seeping in
or cause Galileo to switch off without prior
notice.
- Always open the battery compartment in a
dry and clean environment.
-
Only open the battery compartment to
replace the battery.
1. Dry Galileo with a soft towel.
2. Unscrew the battery cap using a coin
or the dedicated tool.
3. Inspect the o-ring on the battery
cap. If you see traces of seeping
water, damages or defects on the
o-ring, replace the o-ring with an
original UWATEC replacement part
(PN 06.202.693). The o-ring is provided
with the UWATEC battery kit for Galileo
(PN 06.202.872). When replacing the
o-ring, make sure the new o-ring is in
perfect condition and well lubricated,
and that the o-ring, o-ring groove and
sealing surfaces are free of dust and dirt.
4. Remove the old battery and dispose of
it in an environmentally friendly way.
5. Check the polarity of the new battery.
Galileo can be damaged if you do not
insert the battery correctly. Insert the
battery so that the
+
side is pointing
out of the battery case.
6. Screw the battery cap back in place.
Turn the cap until it is flush with the
surface and the slot on the battery
cap is aligned with the mark on the
housing. Damage to Galileo due to
improper placement of the battery cap
is not covered by warranty.
7. Check Galileo by turning it on.
F
NOTE:
- After a dive, Galileo stores tissue
saturation data once an hour
while on the surface until it is
completely desaturated. If you
change the battery while Galileo
has remaining desaturation time,
the tissue data will not be lost,
but Galileo will reference the last
stored data set. As a consequence,
the data displayed on the surface
screen after the battery change
(desaturation time, surface interval,
no-fly time and CNS
O
2
) may be
different from the values displayed
just prior to the battery removal.
- After replacing the battery, you must
set the date and time.
5.2.2 Replacing the battery in the
Smart transmitter
!
WARNING
We recommend having the battery of the
transmitter replaced by an authorized
SCUBAPRO UWATEC dealer. The change must
be made with particular care in order to
prevent water from seeping in. The warranty
does not cover damages due to an improper
placement of the battery.
For best results, use the transmitter battery
set PN 06.204.071, comprising a 3V CR
2/3 AA battery and a 26.00 x 2.00 mm
transmitter cap o-ring.
Summary of Contents for galileo luna
Page 1: ...English English ...
Page 2: ......