W.
REPLACEMENT OF COMPRESSOR
1.
Remove back and front panels on models
ACM 85 and AC 125-175 and the front and left
side panel on model AC 225.
2.
Remove the cover and disconnect the
electrical leads from the compressor junction
box.
3.
Recover the refrigerant from the system
and transfer it in a container so to reclaim or
recycle it.
4.
Unsolder and disconnect both the suction
line and the discharge line from the compressor.
5.
Remove the four compressor mounting bolts
and the compressor from the unit base.
NOTE. It is imperative to install a replace-
ment drier whenever the sealed refrigeration
system is open.
Do not replace the drier until all other repairs
or replacements have been completed.
6.
To install the replacement compressor follow
the above steps in reverse.
NOTE. Thoroughly evacuate the system to
remove moisture and non condensables after
compressor replacement.
Page 32