C.
CLEANING INSTRUCTIONS OF WATER
SYSTEM
1.
Remove the front and the top panels to gain
access either to the control box and to the
evaporator.
2.
Wait till the end of defrost cycle then, with
the help of a normal screwdriver, turn the program
selector head on STAND BY position to temporaly
stop the operation (Fig.8).
Cleaning
3.
Prepare the cleaning solution by diluting in
a plastic container two or three liters of warm
water (45
°
-50
°
C) with a 0,2-0,3 liters of
SCOTSMAN Ice Machine Cleaner.
WARNING. The SCOTSMAN Ice Machine
Cleaner contains Phosphoric and
Hydroxyacetic acids. These compounds
are corrosive and may cause burns if
swallowed, DO NOT induce vomiting.
Give large amounts of water or milk. Call
Physician immediately. In case of external
contact flush with water. KEEP OUT OF
THE REACH OF CHILDREN
4.
Scoop out all the ice cubes stored into the
bin in order to prevent them from being
contaminated with the cleaning solution then
flush out the water from the sump reservoir by
removing the overflow stand-pipe or drain plug.
NOTE. Within few seconds after the removal
of the hand from the Infrared sensing light the
icemaker restarts in freezing cycle.
The ice level control uses devices that sense
light, therefore they must be kept clean
enough so they can "see".
Every month clean/wipe the sensing "eyes"
with a clean soft cloth.
9.
Check for refrigerant leaks.
Page 39
16
15
14
13
2
1
7
8
9
10
3
4
5
6
11
12
Rx Tx
WATER IN VALVE
HOT GAS VALVE
CONTACTOR COIL
FAN MOTOR
WATER PUMP
- EVAPORATOR
- AMBIENT
- CONDENSER
TEMPERA
TURE SENSORS
BIN
COMPRESSOR
TRANSF.
D
ATA
PROCESSOR
ELECTR.
TIMER
DIP
SWITCH
ELECTRONIC CARD
L
N
RELAYS
RELAY
TRIAC
WATER DRAIN VALVE
FIG. 7