2004, Satloc LLC
Page 32 | GPSteer User Guide
An example of an installed valve block is shown below.
2. Install the
Load Sense
Priority Valve
To install the Load Sense Priority Valve:
1. Determine a desirable mounting location for the Load Sense
Priority Valve.
2. Mount the Load Sense Priority Valve.
Tip!
You may only be able to mount the valve using tie wraps
depending on your vehicle.
3. Locate the pressure hose running from the pump to the
steering unit.
4. Disconnect the pressure hose from the pump.
5. Reconnect the hose you disconnected in Step 4 to the “EF”
port on the Load Sense Priority Valve.
6. Connect a new hose from the “LS” port on the GPSteer Valve
Block to the “LS” port on the Load Sense Priority Valve.