Assembly and Operating Manual
Quick-Change-System type SWS-I-011
13
Date printed 28.02.11
7
Maintenance and care
7.1 Maintenance and care intervals
Note
We recommend to replace the waering parts, marked in the Bill of materias (see Chap-
ter 11from page 21) at each service.
Type SWS-I
011
Maintenance intervals (million cycles)
2
Table 6: Maintenance intervals
7.2 Hinweise
CAUTION
!
Comply with the safety instructions in Chapter 1.3, page 3.
In order to assure the proper function of the Quick-Change-System, please consider the
following instructions:
(1) Standard for quality of the compressed air according to DIN ISO 8573-1:
6 4 4
.
(2) Service the quick-change system SWS-I according to Table 6: Maintenance intervals .
-
At every maintenance work the sealing have to be exchanged.
(The complete seal kit can be ordered from SCHUNK. For Id.-No. of the seals, see
chapter 11.1 page 21).
-
The piston bore as well as the sealing have to be lubrified with Renolit HLT 2 or any
equivalent lubricant. (basic greasing)
(3) If not advised differently, all screws and nuts have to be tightened with a starting torque as
per Table 7: Tightening torques and secured with Weicon No. 30243 or Loctite 242
®
and
270
®
.
Pos.
SWS-I-011
12
1,3 Nm
13
1,3 Nm
14
1,3 Nm
18
1,3 Nm
20
0,45 Nm
22
1,3 Nm
33
1,3 Nm
34
0,8 Nm
42
1,3 Nm
44
1,3 Nm
60
1,3 Nm
Table 7: Tightening torques
(For item no. see Assembly, Chapter 10 page 19)
www.comoso.com