Assembly
08.00 | PFH 150- 300 | Assembly and Operating Manual | en | 389270
29
Part gripped (I.D. gripping):
Ø
Clamp the part to be gripped.
Ø
Push the Magnetic switch 1 (1) through the milled opening (3)
into the groove until it switches.
Ø
Fix the magnetic switch (1) in this position, by clamping it in the
groove by tightening the threaded pin.
Ø
Test the function by closing and opening the gripper.