Assembly and installation
Parameter
Description
Possible
content
Type
Read Write
Name
Designation
regOutput
Range
Regulator
output range
Setting the analogue
output for the regulator:
5 = 0-5 V
10 = 0-10 V
20 = 4-20 mA
5
Uint16
X
X
CalWeight Calibration
weight
gravity compensation
calculated from the
calibration process
25
X
Delay
Ramp
Calibration
ramp delay
[ms]
Time in ms until the delay
between 1000 steps of the
calibration process
10
Uint16
X
X
DelayMax
Min
Calibration
max/min
settling time
delay
Settling time delay in ms,
which must be waited for
before measuring the
minimum and maximum
positions during the
calibration process
3000
Uint16
X
X