Assembly and installation
32
02.00 | PW V6 | Assembly and operating manual | en | 389670
5.5 Installing connection cap
NOTICE
Risk of damaging the adapter board!
Fastening the screws too tightly can damage the adapter board.
•
Only fix the screws in place on the adapter board.
Ø
Unfasten the screws (5) from the cover (4) of the connection
cap (2) and remove the cover (4).
Ø
Unscrew the blind plugs (1) from the cover (4) or the connection
cap (2).
Strands
connecting cable
EMC fitting
outer screen
heat-shrink tubing
Ø
Pull the connection cable through the metric cable fitting (6).
Ø
Strip approx. 50 mm of insulation from the connection cable.
Ø
Strip approx. 5 mm of the individual wires.
Ø
Push the outer shielding of the connection cable back over the
cable sheath.
Ø
Fix the shielding in place with shrink hose so that the shielding
at the end of the sheath remains visible.
Ø
Pull the connection cable through the cover (4) or the
connection cap (2) and connect it to the adapter board (3).