background image

 8 

14.  TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

CONNECTED (red) light is 

not on.  

(Models: SC-600A, 

SSC-1500A and SC-1200A)

CHECK (red) light is not on.

(Models: SC-1000A 

and SSC-1000A)

The battery is not connected 

correctly.

Connection to battery is 

reversed.

The battery voltage is less 

than one volt.

Check for poor connection to 

battery and frame. Make sure 

connection points are clean. 

Rock clips back and forth for 

a better connection. 

Correct connection.

Replace the battery or try 

using a manual charger to 

bring above one volt. 

Indicator lights are lit in 

an erratic manner, not 

explained in the Operating 

Instructions. 

A button may have been 

pressed while the charger was 

being plugged in.

Make sure nothing is touching 

the control panel, then unplug 

the unit and plug it in again.

CONNECTED (red) light is 

blinking.

(Models: SC-600A and 

SC-1000A)

Charger in abort mode.

Battery may also be faulty. 

This will happen if the battery 

did not reach full charge within 

48 hours. May be due to a 

very large battery or a bank 

of batteries requiring more 

power than the charger can 

deliver in 48 hours.

Reset the charger by 

unplugging it. Select the 

desired CHARGE RATE 

and battery type again, if 

necessary.

The CHARGED (green) 

light turns on a few minutes 

or less after connecting the 

battery.

The battery may be fully 

charged or recently charged, 

leaving the battery voltage 

high enough to appear to be 

fully charged.

The battery may be faulty 

(sulfated).

If the battery is in a vehicle, 

turn the headlights on for 

a few minutes to reduce 

the battery voltage and try 

charging again. Also try 

a lower CHARGE RATE 

selection.

A sulfated battery will 

eventually accept a charge. 

Continue charging for a few 

hours. The CHARGING 

(yellow) LED will blink. If not, 

have the battery checked or 

call customer service. 

The measured current is 

much lower than what was 

selected.

The charger reached the 

maximum voltage and is 

reducing the current.

No problem; this is a normal 

condition.

Summary of Contents for SC-1000A

Page 1: ...621 5485 Email services schumacherelectric com Web www batterychargers com NO LO DEVUELVA ESTE PRODUCTO A LA TIENDA Contacte Servicios al Cliente para asistencia Tel fono 800 621 5485 Correo Electr n...

Page 2: ...nded attachments Use of an attachment not recommended or sold by Schumacher Electric Corporation may result in a risk of fire electric shock or injury to persons or damage to property 1 4 To reduce th...

Page 3: ...d protective clothing Avoid touching your eyes while working near the battery 2 9 If battery acid contacts your skin or clothing immediately wash the area with soap and water If acid enters your eye i...

Page 4: ...2 Stay clear of fan blades belts pulleys and other parts that can cause injury 6 3 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGAT...

Page 5: ...FIRE 8 1 This battery charger is for use on a nominal 120 volt circuit It will have either a two prong plug or a three prong grounded plug 8 2 If it has a three prong plug the charger must be grounde...

Page 6: ...uched together Battery Connection Indicator If the charger does not detect a properly connected battery the CONNECTED red LED will not light Charging will not begin if the CONNECTED red LED is not on...

Page 7: ...Limit If no button is pressed within 15 minutes after the battery charger is first powered up the charger will automatically switch from tester to charger if a battery is connected In that case the c...

Page 8: ...may also be faulty This will happen if the battery did not reach full charge within 48 hours May be due to a very large battery or a bank of batteries requiring more power than the charger can deliver...

Page 9: ...er is equipped with an auto start feature It will not supply current to the battery clips until a battery is properly connected Unlike traditional chargers the clips will not spark if touched together...

Page 10: ...s no other warranties including but not limited to express implied or statutory warranties including without limitation any implied warranty of merchantability or implied warranty of fitness for a par...

Page 11: ...a limitada expresa y el productor no autoriza ni otorga a alguien a realizar alguna otra obligaci n No existe ninguna otra garant a m s que la descrita en el manual del due o La tarjeta de garant a de...

Page 12: ...12...

Page 13: ...ga el cargador a la lluvia o a la nieve 1 3 Utilice solamente accesorios recomendados El uso de un accesorio no recomendado o suministrado por Schumacher Electric Corporation puede provocar riesgo de...

Page 14: ...a para cargar bater as de pila seca que por lo general se utilizan con artefactos dom sticos Estas bater as podr an explotar y provocar lesiones a personas o da o a la propiedad 2 5 NUNCA cargue una b...

Page 15: ...rma 5 PRECAUCIONES DE CONEXI N EN CC 5 1 Conecte y desconecte los ganchos de salida C C s lo despu s de haber desconectado el enchufe de C A del tomacorriente el ctrico 5 2 Sujete los ganchos a la bat...

Page 16: ...e en posici n frontal a la bater a al realizar la conexi n final 7 6 Conecte el cond n de alimentaci n del cargador de CA al tomacorriente 7 7 Al desconectar el cargador siempre h galo en forma invers...

Page 17: ...de auto marinas y de ciclo profundo No recomendable para uso industrial 10A 12A 15A Proporci n de Carga grande Para bater as de auto marinas y de tipo marino No se destina para las aplicaciones indus...

Page 18: ...podr a llevar hasta 8 horas Si la desulfataci n no tiene xito se anular la carga Vea la secci n de Carga Anulada Finalizaci n de carga La finalizaci n de la carga se indica por medio del LED CARGADO...

Page 19: ...hasta que el LED del ndice de carga se apague 12 INSTRUCCIONES DE MANTENIMIENTO 12 1 Despu s de usar y antes de realizar mantenimiento desenchufe y desconecte el cargador de la bater a ver secciones...

Page 20: ...plena carga dentro de 36 horas Puede ser a causa de una bater a muy grande o banco de bater as que requiere m s fuerza de lo que el cargador puede proveer en 36 horas Reponga el corcel quitandolo Esc...

Page 21: ...r Y corrija todas las conexiones El cargador no enciende a n cuando hay buena conexi n El tomacorriente est muerto Mala conexi n el ctrica Revise los fusibles del interruptor de circuitos que alimente...

Page 22: ...o y da ino para una bater a tratar de forzar dentro de ella un amperaje mayor de lo que puede usar eficazmente en la recarga 15 3 Cuando se presenta un PROBLEMA DE OPERACI N DESCONOCIDO s rvase leer e...

Page 23: ...das a t tulo enunciativo las garant as expresas impl citas o legales incluidas a modo de ejemplo las garant as impl citas de comerciabilidad o adecuaci n a un fin espec fico Asimismo el Fabricante no...

Reviews: