![SCHMITT Acuity AccuProfile 820 Series User Manual Download Page 18](http://html1.mh-extra.com/html/schmitt/acuity-accuprofile-820-series/acuity-accuprofile-820-series_user-manual_1213681018.webp)
Acuity AP820 Laser
Scanners Rev. 3.3
15
4.2.1.1
Power Supply
The Green wire is the Power Supply Common return, also named Ground. It carries
the return current for the power supply.
The White wire is the Power Supply Input to the sensor. The sensor accepts a wide
range from +10 to +30 VDC power and consumes <4 W.
Power supplies from 10 VDC to 30 VDC may be used. Higher voltages will result in
excessive current drawn by the over voltage protection circuitry and may cause
permanent damage.
4.2.1.2
Drain Wire (Clear)
The cable may have an un-insulated wire, drain, that connects the stainless steel
harness plug of the cable. It should also be connected to ground at the power
supply end of the cable.
4.2.2
Ethernet cable
The Ethernet cable uses a M12-D-Coded 4pol Industrial Ethernet cable. The other end
is a standard RJ45 connector.
Connection
Pin-
No.
Function
Cable colors
Note
M12 round 4-
pol
D-coded
female
1
Tx+
green + white
Sending data
Et
2
Rx+
red + white
Receiving data Et
3
Tx-
green
Sending data
Ethernet -
4
Rx-
red
Receiving data Ethernet -
Screen
Connected with the connector plug
housing