Switching frequency, maximum
0.5 Hz
Electrical data - Magnet control
Designation, Magnet control
IN
Switching thresholds
-3 V … 5 V (Low)
15 V … 30 V (High)
Current consumption at 24V
10 mA
Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
40 ms
Classification ZVEI CB24I, Sink
C0
Classification ZVEI CB24I, Source
C1
C2
C3
Electrical data - Safety digital inputs
Designation, Safety inputs
X1 and X2
Switching thresholds
−3 V … 5 V (Low)
15 V … 30 V (High)
Current consumption at 24V
5 mA
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Classification ZVEI CB24I, Sink
C1
Classification ZVEI CB24I, Source
C1
C2
C3
Electrical data - Safety digital outputs
Designation, Safety outputs
Y1 and Y2
Design of control elements
short-circuit proof, p-type
Voltage drop U
d
, maximum
2 V
Leakage current I
r
, maximum
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A
Test pulse duration, maximum
0.5 ms