Performance Level, up to
d
Category
2
PFH value
2.00 x 10⁻⁹ /h
PFD value
1.80 x 10⁻⁴
Safety Integrity Level (SIL), suitable for applications in
2
Mission time
20 Year(s)
Mechanical data
Mechanical life, minimum
1,000,000 Operations
Note (Mechanical life)
When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and
actuating speed ≤ 0.5 m/s)
Angular misalignment between solenoid interlock and actuator,
maximum
2 °
Holding force F
Zh
in accordance with EN ISO 14119
1,150 N
Holding force F
max
, maximum
1,500 N
Latching force, adjustable, position 1
25 N
Latching force, adjustable, position 2
50 N
Type of the fixing screws
2x M6
Tightening torque of the fixing screws, minimum
6 Nm
Tightening torque of the fixing screws, maximum
7 Nm
Mechanical data - Switching distances according EN IEC 60947-5-3
Assured switching distance "ON" S
ao
1 mm
Assured switching distance "OFF" S
ar
20 mm
Switch distance, typical
2 mm
Mechanical data - Connection technique
Termination
Connector M12, 8-pole, A-coded
Length of sensor chain, maximum
200 m
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing
on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31
devices in case of serial diagnostic SD