Operation
46 / 72
EN-US · 30.30.01.01484 · 00 · 01/21
10 Operation
10.1 Safety Instructions for Operation
CAUTION
Depending on the purity of the ambient air, the exhaust air can contain particles,
which escape from the exhaust air outlet at high speed.
Eye injuries
4
Do not look into the exhaust air flow
4
Wear eye protection
CAUTION
When the system is started in automatic operation, components move without ad-
vanced warning.
Risk of injury
4
Ensure that the danger zone of the machine or system is free of persons during auto-
matic operation.
WARNING
Change of output signals when product is switched on or plug is connected
Risk of injury to persons and damage to property due to uncontrolled movements of the
higher-level machine/system!
4
The electrical connection must be performed only by specialists who can evaluate the
effects of signal changes on the overall system.
WARNING
Extraction of hazardous media, liquids or bulk material
Personal injury or damage to property!
4
Do not extract harmful media such as dust, oil mists, vapors, aerosols etc.
4
Do not extract aggressive gases or media such as acids, acid fumes, bases, biocides, dis-
infectants or detergents.
4
Do not extract liquids or bulk materials, e.g. granulates.
10.2 General Preparations
Always carry out the following tasks before activating the system:
1. Before each start of operations, check that the safety features are in perfect condition.
2. Check the ejector for visible damage and deal with any problems immediately (or notify your super-
visor).
3. Ensure that only authorized personnel are present in the working area of the machine or system and
that no other personnel are put in danger by switching on the machine.
There must be no people in the system danger area while it is in operation.