Operating and Menu Concept
EN-US · 30.30.01.01484 · 00 · 01/21
19 / 72
Display
code
Parameter
Possible settings
Explanation
PnP
nPn
Signal type PNP, input/output on = 24 V
Signal type NPN, input/output on = 0 V
dLY
H2 switching
signal delay
Values:
10
,
50
,
200
and
oFF
Delays the switching signals
X1
and
X2
Unit: milliseconds
uni
Vacuum unit
-bA
-ix
-PA
Define the displayed vacuum unit
Vacuum level in mbar
Vacuum level in inHg
Vacuum level in kPa
dPY
Display rotation
5td
Red
Display configuration
Standard
rotated 180°
Eco
Display in ECO
mode
oFF
on
Configure the display
ECO mode is deactivated – the display remains
on
ECO mode is activated – the display switches off
Pin
PIN
Value from
001
to
999
Specify the PIN, lock the menus
If the PIN is
000
, then the device is not locked.
rE5
Reset
YES
Set all parameter values to factory settings.
The factory settings for the parameters are listed in the Technical Data section.
5.4 System Menu
A special menu is available for reading out system data such as counters, the software version, part num-
bers and serial numbers.
1. Open the system menu by simultaneously pressing the
and
buttons for more than 3 seconds.
ð
During activation,
-5-
appears.
2. The parameters are set in accordance with the description in the Main Menu section.
The following table shows an overview of the display codes in the system menu:
Display code
Parameter
Explanation
cc1
Counter 1
Suction cycles
cc2
Counter 2
Number of valve switches
5oC
Software function
Software on the internal controller
Type
Part number
Format of the part no., example: 10.02.02.00383
5nr
Serial number
Provides information about the production period