IO-Link Data Dictionary
SCPSi series
21.10.01.00065/02
29.08.2014
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
[email protected]
18
0x0012
8 bytes
ro
SCPSi_V2
General product name
20
0x0014
30 bytes
ro
SCPSi 00 G2 NC M12-5
Order-Code
250
0x00FA Art
14 bytes
ro
10.02.02.*
Order-Nr.
251
0x00FB
2 bytes
ro
00
Article revision
22
0x0016
2 bytes
ro
03
Hardware revison
23
0x0017 SoC
4 bytes
ro
2.01
Firmware revision
21
0x0015 Snr
9 bytes
ro
000000001
Serial number
24
0x0018
0...32 bytes
rw
***
User string to store location or tooling information
12
0x000C
2 bytes
0 - 7
rw
0
Bit 0:parameter access lock (lock ISDU-write access)
Bit 1: data storage lock
Bit 2: local parameterization lock (lock menu editing)
77
0x004D Pin
2 bytes
0 - 999
rw
0
0 = menu editing unlocked
>0 = menu editing locked with pin-code
69
0x0045 bLo
1 byte
0 - 2
rw
0
0 = Externally controlled blow-off (-E-)
1 = Internally controlled blow-off – time-dependent (I-t)
2 = Externally controlled blow-off – time-dependent (E-t)
71
0x0047 o-2
1 byte
0 - 1
rw
0
0 = NO
1 = NC
73
0x0049 tyP
1 byte
0 - 1
rw
0
0 = PNP
1 = NPN
75
0x004B dLY
1 byte
0 - 3
rw
1
0 = Off
1 = 10ms
2 = 50ms
3 =200ms
74
0x004A uni
1 byte
0 - 2
rw
0
0 = mbar
1 = kPa
2 = inHg
79
0x004F dpy
1 byte
0 - 1
rw
0
0 = standard
1 = rotated
76
0x004C Eco
1 byte
0 - 1
rw
0
0 = off
1 = on
68
0x0044 ctr
1 byte
0 - 2
rw
1
0 = not active (off)
1 = active (on)
2 = active with supervision (onS)
Article number
Article revision
PIN code
Product name
Blow-off mode
Display rotation
Firmware revision
Signal type
Device access locks
OUT2 function
Hardware revision
Product text
Serial number
Initial Setup
Eco-Mode
Production Setup - Profile P0
Vacuum display unit
Air saving function
Output filter
Access Locks
Application specific tag
Parameter
J. Schmalz GmbH
3 of 11
SCPSi Data Dictionary