21 • Schlage • CT5000 user guide
Reader condition
Reader LED
Toggle unsecured
Solid green while unlocked
Toggle secure (relocking)
Solid red
Access denied, frozen secured or
holiday restricted secured
12 red blinks
CT5000 coin cell battery
When installing the CT5000, after power is applied, remove the mylar strip from the coin cell
battery.
When the coin cell battery is low, the CT5000 will provide a delay after acceptance of a valid
credential, and the POWER/TAMPER LED (LED7) will blink rapidly. The reader’s LED will
indicate low battery with one green blink and three red blinks before allowing access.
L
Replace the CT5000’s coin cell battery with Panasonic CR-2025 only. Use of
another battery may present a risk of fire or explosion.
CAUTION! Risk of fire, explosion, and burns. Do not recharge, disassemble, heat
above 100°C or incinerate.
Test
Test the CT5000 with power applied
1. The POWER/TAMPER LED will blink green when the CT5000 lid is removed, and will
light solid green when the lid tamper switch is pressed.
2. Most readers are designed to function independently of the CT5000. If the reader’s LED
and beeper performance is irregular or unexpected, refer to the instructions that came
with the reader.
Schlage button test
L
Performing the Schlage button test will not result in the loss of any CT5000
settings or programming changes.
1. While holding the SCHLAGE button, press and release the RESET button.
2. All relays, on-board LEDs, reader LEDs and reader beeper will be active while the
SCHLAGE button is pressed.
CT5000 in construction mode
1. After programming a Construction Credential (refer to page 15), present a valid
Construction Credential to the reader.
2. The CT5000 Strike relay will activate for the length of the default relock delay. The
Auxiliary relay will not activate.
CT5000 and door file test
1. Present a valid credential to the reader.
2. The CT5000’s STRIKE relay and STRIKE LED will activate for the relock delay, and
the reader’s green LED will blink.
A valid credential will not activate the AUX relay
unless the door file has given the credential authorization to do so.
3. If the credential is not accepted, the reader’s red LED will blink twice.
The audit file is capable of indicating the status for
Anti-Tamper Switch Activated
, and
Door
Propped Open
or
Door Forced Open
. For
Door Propped Open
or
Door Forced Open,
the
Door Position Switch must be configured using the HHD.