PROGRAM LOCK CODES:

11

Code Functions:

The MPC Cobra is manually programmable to have up to 100 codes. The codes can have different functions as
described below. Several types of functions have factory default values which are operational as soon as the lock is
installed. It is highly recommended that the

Programming Code

be changed (this will delete all factory default codes)

and new codes be added. In addition, it is recommended that at least one 

Freeze/Lockout Code

be added - in case

the batteries get completely drained. (See “Battery Information” on below.) All codes can be 3-8 digits in length
(except the Programming code which must be 5-8 digits.) Keep a log of all issued codes. Issue codes exclusively with
all odd or all even numbers - this practice will make it easier to spot duplicate codes, since each keypad button repre-
sents two numbers (for example, code 246 is identical to code 135.)

FUNCTION:

FACTORY DEFAULT:

DESCRIPTION:

P R O G R A M M I N G

N O R M A L

9 7 5 3 1

1 3 5 7 9

1 3 5 1 3 5 

9 1 1 5

N O N E

N O N E

N O N E

TO G G L E

ONE USE

S U P E RVISED

PASS T H R U

FREEZE/LOCKOUT

The programming code puts the lock into a programming mode. It will

not unlock the lock. When a Programming code plus “

*

” is entered the

LEDs alternately flash several times indicating the lock is in a program-
ming mode. If more than 30 seconds pass in between programming
entries, the lock returns to a normal operational state.
Normal codes unlock the lock for the relock time delay. While the lock is
unlocked the green LED will flash. The LED will stop flashing and the
lock will relock.

Toggle codes unlock the lock indefinitely. When the same (or another)
toggle code is entered, the lock will immediately relock. When a toggle
code is entered, the green LED will flash once. The LED will stop flash-
ing and the lock will relock. .

Freeze/Lockout codes prevent other codes from working. The lock can
be locked or unlocked when one is entered. If it is locked, a Pass Thru
code will unlock it but all other codes will not. Only another Lockout code
will reverse the effect.

One Use codes unlock the lock for the relock time delay. They will only
work once and then are deleted from memory. They can used again if
they are programmed (added) into memory again.

Supervised codes require that two different supervised codes entered in
order to unlock the lock for the relock time delay.

Pass Thru codes will  unlock the door for the relock time delay even if
the door is in the lockout mode.

BATTERY INFORMATION:

The MPC Cobra uses four, standard AA batter-
ies. The batteries should provide enough life for
approximately 80,000 lock/unlock cycles. When
the batteries are running out the lock provides
two different modes of low battery indication:
First, when a code is entered, the red LED will
flash twelve times before the lock executes the
command of the code. This is an indication that
it is time to replace the batteries. The lock will
go for about 500 cycles in this condition. After it
reaches a certain point the lock will go into “Low
Battery Lockout” mode. A Freeze/Lockout code
will need to be entered in order gain access. If
the batteries are not changed, the lock will even-
tually not work and manual key override (if
installed) will need to be used.

CLEARING MEMORY:

Clearing memory will delete all programmed codes and restore
factory default codes. If the memory ever needs to be erased fol-
low the steps below:

1. Remove the inside escutcheon. Remove one of the batteries.
2. Press any key.
3. Hold down the “*” key and reinstall the battery. Continue holding
the “*” key down. The red LED will flash a few times and then stay
on.
4. Release the “*” key. 
5. Install the inside escutcheon.

Note: to return the lock to the factory default relock time delay, do
steps 1-4 twice in a row.

FORM 57018 Rev. B

02-10-2005

PAGE 7

Summary of Contents for COBRA MPM

Page 1: ...tructions and Users Manual M MP PM M M MP PM MA A MORTISE LOCKING SYSTEM FORM 57018 Rev B 02 10 2005 AUTOBOLT LATCHBOLT M MP PM M M MP PM MA A Manually Progammed Mortise Lockset Up to 100 codes can be manually programmed ...

Page 2: ...RA MPM FORM 57018 Rev B 02 10 2005 PAGE 2 Use the paper template or information below to prep door latch and frame Dimensions are in inches 1 PREP DOOR FRAME FOR LOCK DOOR PREP FOR COBRA SPM MPM ALL HOLES ARE THRU ...

Page 3: ...lt can be removed C Rotate bolt and reinstall on to shaft Do not remove spring D Apply thread locking compound to set screw Loctite 242 recommended E Install and tighten set screw from other side as shown F Remove change pin 5 32 SOCKET CAP SCREW LOCTITE 242 RECOMMENDED OUTSIDE ESCUTCHEON OUTSIDE HANDLE CHANGE PIN LOCK CASE BOLT AUTOBOLT SHOWN TO CHANGE HAND OF LEVERS A Loosen 5 32 socket cap scre...

Page 4: ...INSTALLATION INSTRUCTIONS SCHLAGE COBRA MPM FORM 57018 Rev B 02 10 2005 PAGE 4 4 INSTALL STRIKE 3 INSTALL MORTISE LOCK STRIKE BOX STRIKE STRIKE SUPPLIED WITH PROCUCT MUST BE USED FOR PROPER OPERATION ...

Page 5: ...UNTER CLOCKWISE TO ENGAGE LOCKING PIN D REMOVE KEY LOCK IS NOW OPERATIONAL OPERATION EITHER THE CYLINDER PLUG OR THE IC CORE MUST BE INSTALLED FOR THE LOCK TO OPERATE REMOVAL OF THE CORE OR PLUG AUTO MATICALLY UNLOCKS THE LOCK IT IS RECOMMENDED THAT AN IC CORE BE INSTALLED IN CASE IT EVER BECOMES NECESSARY TO UNLOCK THE LOCK USING MECHANICAL MEANS REMOVE TAPE IF PRESENT NOTE 6 PIN IC CORE CYLINDER...

Page 6: ...LATION INSTRUCTIONS SCHLAGE COBRA MPM FORM 57018 Rev B 02 10 2005 PAGE 6 8 MAKE WIRING HARNESS CONNECTIONS 10 INSTALL ARMOR FRONT 9 INSTALL INSIDE SPINDLE SPRING AND INSIDE ESCUTCHEON PLUG CONNECTORS TOGETHER ...

Page 7: ...ill relock Freeze Lockout codes prevent other codes from working The lock can be locked or unlocked when one is entered If it is locked a Pass Thru code will unlock it but all other codes will not Only another Lockout code will reverse the effect One Use codes unlock the lock for the relock time delay They will only work once and then are deleted from memory They can used again if they are program...

Page 8: ...D MORE TO END 3 1 1 5 TO DELETE CODES ENTER PROG CODE ENTER CODE TO DELETE MORE TO END 5 PRESS 1 FOR 1 SEC AND OR 5 FOR 5 SEC THE TIMES WILL ADD Use the steps on this page to program codes into the lock The key is used like the ENTER key is on a computer After pressing the key wait for the red and green LEDs to stop flashing before proceeding to the next step If at any time the red LED stays on wh...

Reviews: