6. INSTALL INSIDE BASEPLATE ASSEMBLY:
7. INSTALL 6- or 7-PIN IC CORE CYLINDER
(RECOMMENDED):
A. HOLD LOCK IN HORIZONTAL
POSITION AS SHOWN AND PUSH
PLUG IN UNTIL PIN FALLS OUT.
REMOVE PLUG.
B. INSERT CYLINDER CON-
TROL KEY INTO CORE AND
TURN CLOCKWISE TO
RETRACT LOCKING PIN.
C. PUSH CYLINDER CORE
INTO LOCK - RESISTANCE
WILL BE NOTICEABLE.
TURN KEY COUNTER-
CLOCKWISE TO ENGAGE
LOCKING PIN.
D. REMOVE KEY.
LOCK IS NOW
OPERATIONAL.
OPERATION:
EITHER THE CYLINDER PLUG
OR THE IC CORE MUST BE
INSTALLED FOR THE LOCK
TO OPERATE. REMOVAL OF
THE CORE OR PLUG AUTO-
MATICALLY UNLOCKS THE
LOCK. IT IS RECOMMENDED
THAT AN IC CORE BE
INSTALLED IN CASE IT EVER
BECOMES NECESSARY TO
UNLOCK THE LOCK USING
MECHANICAL MEANS.
REMOVE TAPE
(IF PRESENT)
NOTE:
6-PIN IC CORE CYLINDERS
REQUIRE THAT THE
ADAPTER IS INSTALLED TO
MAKE THEM AS LONG AS A 7-
PIN CYLINDER. THE ADAPTER
IS INCLUDED IN THE SCREW
PACK. DO NOT INSTALL THE
ADAPTER IN A 7-PIN IC CORE
CYLINDER.
5. INSTALL OUTSIDE SPINDLE &
ESCUTCHEON: