INSTALLATION
Pull out the extension cable to the desired length and lock. Connect the charging socket to
the electrical vehicle (EV). Switch on the automatic cable reel with integrated charging
electronics using the rocker switch (ON / OFF). A flashing LED (STATUS CONTROL)
signals operational readiness. If this is not the case, the fuses must be checked. Observe
the description under “OPERATING AND SIGNALING ELEMENTS”.
If the charging electronics are equipped with an AC / DC sensitive residual current
monitoring device, this must be checked for proper function before each charging process.
It is necessary that the charging process is deactivated (no vehicle connected). Observe
the notes under "OPERATING AND SIGNALING ELEMENTS"
ATTENTION
Danger to life from electric current!
Safety for life is only guaranteed if the monitoring device functions properly.
Therefore, a device test (by the charge controller) must be carried out before each
charging process!