![Schill FT 038 e-mobility Installation And Operating Instructions Manual Download Page 8](http://html.mh-extra.com/html/schill/ft-038-e-mobility/ft-038-e-mobility_installation-and-operating-instructions-manual_1212031008.webp)
automatic cable rewinder FT 038 e-mobility with integrated charging electronic
installation and operating instruction
installation
and operation instruction FT 038 e-mobility miL - A4 -
version B
Seite 8
11.03.2021
Schill GmbH & Co. KG; Bruckstraße 44; 70734 Fellbach
FUSE:
Protection of the charging electronics
Signal lamp STATUS DEVICE (lamp green):
AC / DC sensitive residual current device: no device fault
Pushbutton TEST / RESET:
The device test for residual current monitoring is carried out with the push button.
The device test is carried out via a connected measuring current transformer. The effective
value of the direct current component contained in the differential current and the
alternating current component below the cut-off frequency is formed. The alarm relays
switch when the limit values of I
Δ
n
≥ DC 6 mA and / or effective value I
Δ
n
≥ 30 mA are
exceeded. The regular check increases the safety of the charging process and prevents
long-term drifting of the residual current measurement.
Fault storage is integrated in the residual current monitoring. An error that has occurred or
a test that has been carried out must be reset manually using the pushbutton. (The error
storage can optionally be switched off, then the reset takes place automatically as soon as
the residual current fulfills the connection condition.
THERMAL SWITCH:
Switches off the charging process when a critical temperature is reached
If the electronics of the automatic cable winder are defective, please contact us (see
"CONTACT").
TECHNICAL DATA
The cable reels consist of a plastic drum core with coated steel discs and a steel bracket.
Is corrosion resistant and has very good winding and running characteristics due to the
ball-bearing axle. The stable construction is designed for operation in factories and
workshops. The cable reels are supplied as standard without a plug device.
•
Spiral spring for approx. 30. 000 operations
•
Disengageable cable locking device
•
High quality flat slip rings 240 / 400V AC - 16A with double contacts
•
flexible and lockable cable guide
•
Mounting fixture WB 038 for wall installation (standard)
•
Mounting fixture DB 038 for ceiling installation (optional)
•
Ambient temperature range: -20°C bis 40°C
•
IP classification: IP 42
•
Construction: protection class I
•
Protection / internals
➢
Temperatur protection device:
▪
self-retaining Thermal switch (56°C±5°C)
▪
self-retaining Thermal switch (O65°C±5°C / C50°C)
➢
Glass bulb fuse 5x20 400mA slow
➢
Installation contactor 4way 40A