16 english
• Type of current of the motor
• Data recorded on the machine’s rating plate
• Data recorded on the switch’s rating plate
If a motor has to be returned, it must always be dispatched
with the complete driving unit and switch.
Special Accessories
Cross cutting jig
Item no. 5100 2100
Slide carriage
Item no. 7951 0000
Plate cutting device
Item no. 7961 0000
Slide handles
Item no. 7963 1000
Automatic starter
Item no. 7910 4010 type ALV 2
Item no. 7910 4020 type ALV 10
Troubleshooting
Failure Possible
cause Solution
Saw blade gets loose after
a) Fastening nut tightened
a) Tighten fastening nut, M20 left-handed thread
turning off the motor
insufficiently
Motor does not start
a) Fastening nut tightened insufficiently a) Check the mains fuse. b) Extension cable de-
fect
b) See “Electrical Connection” in the operating manual, pages
GB 16
c) Connections on
the motor or
c) Have it checked by an electrician switch defect
Brake does not bleed
d)
Motor or switch defect
d) See “Electrical Connection” in the operating manual, pages
GB 16
Motor runs forward or
Capacitor defect
Have it exchanged by an electrician
backwards
No motor output
Overload by dull saw
Insert a sharpened saw blade; motor can be
turns off automatically
blade, thermoprotection is triggered
turned on again after the cooling period
Burns on the cutting
a) Fastening nut tightened insufficiently a) Insert a sharpened saw blade
surface
b) Wrong saw blade
b) Insert saw blade with 20 or 28 teeth for longi-
tudinal cuts
c) with longitudinal cuts
c) Longitudinal stop not parallel
c) Exchange the longitudinal stop
d) with cross cuts
d) Slide carriage not parallel
Align the slide carriage with the saw blade