16
In the event of enquiries please specify the following data:
1. Motor manufacturer
2. Type of current of the motor
3. Data recorded on the machine’s rating plate
4. Data recorded on the switch’s rating plate
If a motor has to be returned, it must always be dispatched
with the complete driving unit and switch.
Optional equipment
Sliding table carriage
1200 mm:
Part no.
7951 0000
1500 mm:
Part no.
7951 0901
Sliding table carriage
1300 mm:
Part no.
5278 0701
Table width extension
Part no.
7961 0901
Automatic switch-on unit
Typ ALV 2: Part no.
7910 4010
Typ ALV 10: Part no.
7910 4020
EC Declaration of Conformity
We,
scheppach Fabrikation von Holzbearbeitungsmaschinen GmbH
Günzburger Str. 69, D-89335 Ichenhausen
hereby declare that the ma-
chine named below correspondends to the relevant safety and health
requirements of the EC guide lines specified below in its design and
construction and in the version which we introduced to the market.
This declaration becomes invalid if changes are made to the machine
without our consent.
Machine description:
Circular saw
Machine model:
tku 4000
Relevant EC directives:
EC machine directive 98/37/EG (< 28.12.2009), EC machine directive
2006/42/EG (> 29.12.2009), EC Low voltage directive 2006/95/EWG,
EC-EMV directive 2004/108/EWG.
Applied harmonized European Standards:
EN12100-1, EN12100-2, EN294, EN349, EN418, EN847-1, EN954-1,
EN1088, EN1870-1, EN60204-1, EN55014, EN60555-2, EN60555-3
Applied national technical standards and specifications, especially:
ISO 7960
Notified body within the meaning of Annex VII
Prüf- und Zertifizierungsstelle, Fachausschuss Holz, Vollmoellerstraße
11, 70563 Stuttgart-Vaihingen
Engaged for
(EG-Baumusterbescheinigung)
Date
Ichenhausen, 01.09.2007
Signature:
on behalf of Wolfgang Windrich (Technical manager)
Troubleshooting
Failure
Possible cause
Solution
Saw blade gets loose after turning off
the motor
a) Fastening nut tightened insuffi-
ciently
a) Tighten fastening nut, M20 left-
handed thread
Motor does not start
a) Fastening nut tightened insuffi-
ciently
a) Check the mains fuse.
b) Extension cable defect
b) See “Electrical Connection” in the
operating manual, pages
GB 16
c) Connections on the motor or switch
defect
c) Have it checked by an electrician
Brake does not bleed
d) Motor or switch defect
d) See “Electrical Connection” in the
operating manual, pages
GB 16
Motor runs forward or backwards
Capacitor defect
Have it exchanged by an electrician
Engine is giving full power,Saw blade is
running to slow
Drive belt too slack
Stretch drive belt
No motor output, turns off automati-
cally
Overload by dull saw blade, thermopro-
tection is triggered
Insert a sharpened saw blade; motor
can be turned on again after the cool-
ing period
Burns on the cutting surface
a) Fastening nut tightened insuffi-
ciently
a) Insert a sharpened saw blade
c) with longitudinal cuts
c) Longitudinal stop not parallel
c) Exchange the longitudinal stop
d) with cross cuts
d) Slide carriage not parallel
d) Align the slide carriage with the saw
blade