Electrical Connection
The electric motor installed is ready to use. The terminal
complies with the relevant VDE and DIN regulations. The
electrical terminal on the customer’s side and any extensi-
on cable used must comply with these regulations.
• The product meets the requirements EN 61000-3-
11 and is subject to specific terminal conditions.
This is that the use of any arbitrary connection
points is not permitted.
• Under unfavorable mains conditions the device can
cause temporary voltage fluctuations.
• The product is intended for the use at connection
points only, that
a) do not exceed the maximum permissible mains
impedance “Z” (Zmax = 0.382
Ω
), or
b) have a continuous current-carrying capacity of at
least 100 A per phase.
• You as the user need to make sure, even consulting
your power company, if necessary, that your con-
nection point at which you want to run the product,
meets one of the two above mentioned requirements
a) or b)
Inspect the power cords regularly for damage. During this
inspection, make sure that the power cord is not con-
nected to the mains supply.
The power cords must comply with the applicable VDE
(German Association for Electrical, Electronic, and In-
formation Technologies) and DIN (German Institute for
Standardization) regulations. Use only power cords with
H 07 RN designation.
A type label on the power cord is prescribed.
Faulty power cords
Power cords often suffer insulation damage.
The causes of this are:
• Pinching, when power cords are routed through win-
dows or door cracks.
• Bending due to improper attachment or routing of the
power cords.
• Cuts due to driving over the power cords.
• Insulation damages caused by yanking it out of the
power outlet.
• Cracks in the insulation because of ageing.
Such faulty power cords must not be used and are, due
to the damaged insulation, a
danger to life!
AC motor 230 V/ 50 Hz
Power supply 230 volts / 50 Hz.
Power cord and extension cord must have 3 conductors =
P + N + PE. - (1/N/PE).
The extension wires must have a cross-section of at least
1.5 mm².
The power supply must be protected by a 16 A (or less)
circuit breaker.
Three-phase motor 400 V/ 50 Hz
Power supply 400 volts / 50 Hz.
Power cord and extension cord must have 5 conductors
= 3 P + N + PR. - (3/N/PE).
The extension wires must have a cross-section of at least
1.5 mm².
The power supply must be protected by a 16 A (or less)
circuit breaker.
After connecting the power supply or after relocating,
check the direction of rotation. Invert polarity if neces-
sary.
Turn the polarity inverter inside the power plug.
Start-up
Once connected to the mains supply, your Scheppach
machine is operational.
Pay attention to the running direction of the grinding belt
during start up; please notice the arrow sticker on the
device. When connected to the grid, the rotating direction
of the three-phase AC motors might be reversed. If neces-
sary, the polarity of the wall socket should be changed.
Attention: this may only be performed by a certified elec-
trician!
Always check the sanding belt for intactness prior to each
start up. This is of particular importance for used grinding
belts or belts which were mounted on the machine for a
longer period.
Grinding belt run, Fig. 8
Check for consistent and smooth running of the grinding
belt while the machine is switched on. If required, adjust
with the adjustment handle; notice the arrow indication
on the handle.
Attention: Replace the defected sanding belts immediately!
To do so, please refer to the (Maintenance) chapter.
Notices on operation
Observe the safety instructions!
Start the grinding process only when the grinding belt
is tensioned and the grinding machine has reached the
maximum idle speed.
Do not turn off the machine as long as the work piece is
in contact with the sanding belt.
Surface grinding, Fig. 9
Perform surface grinding work while the grinding belt is
running horizontally.
Place work pieces with up to 78 cm length at the sand-
ing stop plate.
For work pieces with a length over 78 cm, the sanding
stop plate must be hinged down.
For a change from surface grinding to angle grinding, the
height-adjustable traverse table must be in the lowest
position.
Angel grinding, Fig. 10, 11, 12
For angle grinding work, the sanding belt must be set to a
vertical run. The pivoting of the grinding table must only
be done from the rear side of the machine.
• Turn off the machine and disconnect the mains plug.
• Lift the locking lever to release.
• To pivot the table, hold the motor console with the left
hand and the sanding stop plate with the right hand.
Never touch the grinding table with the right hand!
There is a risk of injury such as crushing the fingers
between the grinding table and the traverse table during
pivoting.
• Press the locking lever down in order to adjust and
lock in place.
Summary of Contents for 1903301801