7.3.45
I. Power plant operating unit MCU3 BG
(cont.)
B) Functional description (cont.)
7.3 Error Messages – Device failure or error (ERROR) (cont.)
Number
FEHLER_COMSUPPLYSWITCH (86)
Display
Supply sw. com malfunc.
Description
The data transmission from the supply-switch to the power plant control unit is
interrupted. This indicates a wiring interruption/removal or a defect in the supply
switch. No effects are to be expected in the event of removal or wiring interruption. In
the event of a defect, engine operation may not be possible or only limited engine
operation may be possible.
Text
Supply-switch communication malfunction. Engine operation may be restricted.
Short text
Supply sw. com malfunc.
Number
FEHLER_SUPPLYSWITCH (87)
Display
Supply sw. malfunc.
Description
Internal error in the supply switch. Engine operation may not be possible or only
limited engine operation is possible.
Text
Supply switch malfunction. Engine operation may be restricted.
Short text
Supply sw. malfunc.
Number
MCU3_BG_ERROR_SG_OFFLINE (201)
Display
Com malfunc.
Description
The data transmission from the power plant control unit to the operating unit is
disturbed. This indicates a defective wiring or a defective control unit.
Since there is no information on the cooling water temperature, overheating of the
engine cannot be ruled out. As long as the fault persists, operation on the operating
unit is not operable. Use emergency system.
Text
Communication malfunction. Engine overheat possible. All operations
disabled. Use emergency mode!
Short text
Com malfunc.
Number
MCU3_BG_ERROR_FIRMWARE (202)
Display
BG prog. corrupt
Description
The program memory of the power plant operating unit is damaged. The program is
stopped permanently for safety reasons. No operation is possible on the operating
unit. Use emergency system. This problem can possibly be solved by updating the
operating unit in the boot menu.
Text
BG program corruption. All operations disabled. Use emergency mode!
Short text