7.3.39
I. Power plant operating unit MCU3 BG
(cont.)
B) Functional description (cont.)
7.3 Error Messages – Device failure or error (ERROR)
Number
FEHLER_WASSERPUMPE (60)
Display
Cool pump malfunc.
Description
Power supply or wiring to the cooling water pump is interrupted. Detected when
switched off due to lack of voltage at the low-side switch.
Text
Cooling pump malfunction. Engine overheat possible. Limited Engine operation time.
Short text
Cool pump malfunc.
Number
FEHLER_WASSERPUMPE_STROM (61)
Display
Cooling malfunction
Description
Current consumption of the water pump too high or too low. Possible causes: Pump
sucks air, pump is blocked, water pipe is blocked or broken, water level is too low.
Text
Engine cooling malfunction. Overheat possible. Limited engine operation time.
Short text
Cooling malfunction
Number
FEHLER_SERVO (62)
Display
Prop. brake malfunc.
Description
The servo motor for the propeller brake has failed. Possible causes are e.g.: short
circuit in the H-bridge, interruption of the power supply or the supply line.
Text
Propeller brake malfunction. Manual break operation required.
Short text
Prop. brake malfunc.