SCHEMPP-HIRTH FLUGZEUGBAU GmbH, KIRCHHEIM/TECK
Ventus-3M „Performance“
FLIGHT MANUAL
March 2019
Revision –
7.3.31
I. Power plant operating unit MCU3 BG
(cont.)
B) Functional description (cont.)
6
. Operating notifications (cont.)
Number
INFO_FEHLERTANKKALIBRIERUNG (15)
Display
Tank calib. failed
Description
After triggering a tank calibration: More than 30% deviation from reference value. The
calibration is discarded and the previous calibration is retained.
Text
Fuel tank calibration failed. Fill tank completely and restart calibration!
Short Text
Tank calib. failed
Number
INFO_EINAUSFAHR_BLOCKIERUNG (16)
Display
Engine move paused
Description
When the unit is turned on or the emergency mode is exited, a switch status is found
that the spindle drive would immediately start moving (i.e. ignition is on when the
power plant is retracted, or ignition is off when the power plant is extended, or manual
operation switch is pressed). However, the immediate start is prevented for safety
reasons. To start the spindle drive, the corresponding switch must first be released
and reset. (e.g. ignition off-on or on-off.)
Text
Engine movement paused. Switch ignition off and back on or vice versa!
Short Text
Engine move paused
Number
INFO_STARTER_BLOCKIERUNG (17)
Display
Engine start blocked
Description
Case 1:
On turning on the operating unit, the ignition is ON, the power plant is fully
extended and the starter button is pressed so that the engine would start immediately.
However, immediate engine start is prevented for safety reasons. To start the engine,
the starter button must first be released and reset.
Case 2:
On turning on the operating unit, the ignition is OFF, the Power plant is fully
extended and the propeller is not in the retract position, so it cannot be retracted.
However, the engine starter would be released in this state despite the ignition being
deactivated to enable propeller positioning. However, an engine start is prevented for
safety reasons. To start the engine, the ignition must first be switched ON and OFF
again.
Remedy in both cases: Release starter button, ignition OFF/ON.
Text
Engine start blocked. Release start button, switch ignition off and back on or vice
versa!
Short Text
Engine start blocked