SCHEMPP-HIRTH FLUGZEUGBAU GmbH, KIRCHHEIM/TECK
Ventus-3M „Performance“
FLIGHT MANUAL
March 2019
Revision –
7.3.42
I. Power plant operating unit MCU3 BG
(cont.)
B) Functional description (cont.)
7.3 Error Messages – Device failure or error (ERROR) (cont.)
Number
FEHLER_CAN (73)
Display
Engine malfunc.
Description
No reception at the CAN bus of the Trijekt engine control unit for >0.5 sec. This
indicates a defect in the Trijekt engine control unit, a triggered Trijekt fuse or a wiring
defect in the CAN bus. If there is a wiring defect or the Trijekt-fuse tripped, the engine
might still run. Engine operation is not possible with a Triject-defect.
Text
Engine control malfunction (CAN).
Short text
Engine malfunc.
Number
FEHLER_MOTORSENSOR (75)
Display
Engine malfunc. (75)
Description
Error signal from the Trijekt Engine control unit: Crankshaft sensor defective. No
engine operation possible.
Text
Engine malfunction (75): Crankshaft sensor failure
Short text
Engine malfunc. (75)
Number
FEHLER_LUFTDRUCK_INTERN (77)
Display
Engine malfunc. (77)
Description
Error signal from Trijekt Engine control unit: mixture regulation. Engine start and
operation may no longer be possible.
Text
Engine malfunction (77): Air mix regulation
Short text