SCHEMPP-HIRTH FLUGZEUGBAU GmbH, KIRCHHEIM/TECK
Ventus-3M „Performance“
FLIGHT MANUAL
March 2019
Revision –
7.3.23
I. Power plant operating unit MCU3 BG
(cont.)
B) Functional description (cont.)
1.3 Fuel content / Fuel menu:
Important note:
Prerequisites for making settings in the tank menu:
-
Completely filled fuselage tank
-
Ignition OFF
-
Power plant completely retracted (retracted limit switch actuated)
Calib. main tank:
If the correct number of litres is not displayed despite the fuel tank being completely filled,
the fuel measurement may be to recalibrated. To do this, the fuel tank must be completely
filled.
With the function
Calib. Main tank
in the
Fuel menu
the calibration can be carried out.
Select the function with the rotary selector switch and press to select.
If a calibration has been carried out successfully, a new value is entered for Tankfactor.
The calibration is now complete. After a few moments, the fuel content is corrected to the
target value.
If the calibration was not successful, the error message
Tank calib. failed
appears. The
previous
Tankfactor
value is still used. The cause of the error can be an incompletely
filled tank, a too high alcohol content in the fuel or sloshing of the fuselage tank contents
during the calibration procedure.