Instruction Manual for Electroblock EBL 271
4
Date: 14.02.2011
811.523 BA / EN
Y
ATTENTION!
The electroblock, 12V consumers and the connected devices can be da-
maged if the thresholds for the 230V supply are exceeded. Note therefore
the following:
F
It is essential that the generator conforms to the specifications of the
mains supply.
F
Do not connect the generator until it is running smoothly.
F
Do not connect the electroblock to the mains supply on board passen-
ger vehicle ferries (a correct mains supply is not always guaranteed
on board these ferries).
3.2 Changing the battery
Y
ATTENTION!
Using incorrect battery types or incorrectly designed batteries results in
damage to the battery or devices connected to the electroblock. So there-
fore:
F
Batteries should only be changed by qualified personnel.
F
Follow the battery manufacturer’s instructions.
F
Only connect the electroblock to 12V power supplies with rechargea-
ble 6-cell lead gel or lead acid batteries. Do not use any unsuitable
battery types.
Y
Normally only batteries of the same type and capacity should be used,
i.e. the same as those installed by the manufacturer.
Y
It is possible to swap lead acid batteries with lead gel batteries. However,
swapping from lead-gel batteries to lead-acid batteries is only possible in
certain cases. Contact the vehicle manufacturer for more information.
"
Electrically disconnect the battery from the electroblock. To do this, ena-
ble battery isolation on the IT .../LT .... control and switch panel (see also
Section 3.1).
"
Replace battery.
"
After changing the battery, recheck which type of battery has been inser-
ted.
Y
DANGER!
Incorrectly setting the battery selector switch poses a risk of explosion due
to the formation of detonating gas. So therefore:
F
Move the battery selector switch to the correct position.
"
Disconnect the electroblock from the mains before adjusting the battery
selector switch.
Generator operation and
passenger vehicle
ferries
Changing the battery