Instruction Manual for Electroblock EBL 271

5

Date: 14.02.2011

811.523 BA / EN

1

Fig. 1

Battery selector switch

"

Move the battery selector switch (Fig. 1, Pos. 1) into the correct position:

F

Lead gel battery: Move the battery selector switch to ”Lead-gel”.

F

Lead acid battery: Move the battery selector switch to ”Lead-acid”.

F

AGM battery: Schaudt GmbH recommends charging AGM batteries

with their chargers in switch position ”Lead-gel battery”.

We believe that AGM batteries can be charged perfectly this way. Ho-

wever, suitability must be checked using information from the battery

supplier and the charging parameters of Schaudt equipment. The

charging parameters are specified in the operating and installation

instructions.

"

Start up the system as described in Section 3.1.

3.3 Faults

A fault in the power supply system is usually caused by a blown fuse.

Please contact our customer service department if you cannot rectify the

fault using the following table.

If this is not possible, e.g. if you are abroad, you can have the electroblock

repaired at a specialist workshop. In this case you must ensure that the war-

ranty is not invalidated by incorrect repairs being carried out and Schaudt

GmbH will not accept any liability for damage resulting from such repairs.

The following functions are protected by a polyswitch fuse:

F

12V indicator

F

Battery 1

F

Output D+

F

Marker lights

If there is a fault here, the cause of the overload must be rectified. After-

wards, the relevant supply circuit must be interrupted for a period of about 1

minute (e.g. by removing the relevant connector, see block diagram on Page

14). The polyswitch fuses are reset automatically during this period.

AGM batteries

Starting up

the system

Flat vehicle fuses

Polyswitch fuses

Summary of Contents for Electroblock EBL 271

Page 1: ...al Electroblock EBL 271 Table of contents 1 Safety information 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 2 Introduction 3 3 Operation 3 3 1 Starting up the system 3 3 2 Changing the battery 4 3 3 Operating faults 5 3 4 Closing down the system 7 4 Application and functions in detail 8 4 1 Battery functions 9 4 2 Additional functions 10 5 Maintenance 10 Appendix 11 ...

Page 2: ...ay affect the safety of persons or the proper functioning of the device must be repaired immediately by specialists Y DANGER 230 V unit carrying mains voltage Risk of fatal injury due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged no longer use the device and isolate it from the power supply F Ensure that no liqui...

Page 3: ... or when retrofitting accessories see Section 3 2 and the installation instructions for the EBL 271 3 1 Starting up the system Y ATTENTION Incorrect electroblock settings can result in damage to connected devices Therefore prior to starting F Ensure the living area battery is connected F Ensure that the battery selector switch Fig 3 Pos 9 is set to the correct position for the battery installed Us...

Page 4: ...troblock to 12V power supplies with rechargea ble 6 cell lead gel or lead acid batteries Do not use any unsuitable battery types Y Normally only batteries of the same type and capacity should be used i e the same as those installed by the manufacturer Y It is possible to swap lead acid batteries with lead gel batteries However swapping from lead gel batteries to lead acid batteries is only possibl...

Page 5: ...aults A fault in the power supply system is usually caused by a blown fuse Please contact our customer service department if you cannot rectify the fault using the following table If this is not possible e g if you are abroad you can have the electroblock repaired at a specialist workshop In this case you must ensure that the war ranty is not invalidated by incorrect repairs being carried out and ...

Page 6: ...onsumers not required Defective electroblock Contact customer service Living area battery is not h d d i bil Defective alternator Check the alternator g y charged during mobile operation battery voltage No voltage on D input Check the fuse and wiring operation battery voltage below 13 0 V D switch on the electro block is not set correctly Set the switch according to the D signal from the vehicle 1...

Page 7: ...cessive ambient temperature or lack of ventilation Always prevent the device from overheating nevertheless Y If the automatic shutdown mechanism of the battery monitor is triggered fully charge the living area battery 3 4 Closing down the system A battery is isolated by switching off the main switch on the IT LT con trol and switch panel and by disconnecting a plug connector Y ATTENTION Damage to ...

Page 8: ...F the 12V distribution unit F fuses for the 12V circuits An IT or LT control and switch panel must be connected for operation These devices control the electrical functions in the vehicle s living area inc luding accessories There is also an option to connect an additional charger and a solar charge regulator Flat vehicle fuses protect the various circuits The two D outputs and the output for the ...

Page 9: ... gel and lead acid With LT control and switch panel approx 4 mA depending on the control and switch panel used under the following condi tions F No mains connection F Living area battery voltage 12 6V F 12V main switch OFF Living area battery Characteristic charging curve IUoU End of charge voltage 14 3V Charging current 18A Voltage for float charge 13 8V with automatic switch function Starter bat...

Page 10: ... 230V mains is connected to the electroblock This output is suitable for supplying the side marker lights of the motorhome The associated voltage output is switched on as soon as control signal Ve hicle lighting ON of the basic vehicle is applied at the relevant control input of the EBL 271 This output provides a supply voltage to operate an electric fold away bed The voltage is only applied when ...

Page 11: ... the basis for this declaration application submitted for appro val date 04 2010 Typgen no e1 72 245 2009 19 5664 __ EC gen mark e1 035664 Schaudt GmbH Elektrotechnik Apparatebau Planckstraße 8 88677 Markdorf Germany B Special fittings accessories Schaudt IT LT switch panel required for operation C Customer service Schaudt GmbH Elektrotechnik Apparatebau Planckstraße 8 D 88677 Markdorf Phone 49 75...

Page 12: ...pe _______________________ Item no _______________________ Vehicle Manufacturer _______________________ Model _______________________ Own installation Yes No Upgrade Yes No Upstream overvoltage protection Yes No Following fault has occurred please tick Electrical consumers do not work which please specify below Switching on and off not possible Persistent fault Intermittent fault loose contact Oth...

Page 13: ... 1 2 lighting continual positive for radio 4 Block 5 D input output battery sensor 5 Block 4 Consumers not connected 6 Block 3 Additional charger 7 Block 2 Solar regulator 8 Block 1 Refrigerator 9 D signal changeover switch 10 Selector switch for acid gel battery 11 Assembly flaps 12 Flat vehicle fuses 13 Mains connector 14 Housing 1 2 3 Fig 4 Layout of EBL 271 electroblock rear 1 Connector for li...

Page 14: ...Minifit SR 4F block 1 batt 1 for refrigerator Minus batt 1 for Negative refrigerator Refrigerator lines must be routed separately from other battery lines to the battery terminals Refrigerator refrigerator 20A Negative living area battery sensor sensor living area battery D input MNL socket 4F block 5 D point 2A 2A D point Pump Connected negative pole of pump Light 1 Light 2 Spare 1 MNL socket 12F...

Reviews: