2019/10/07
Operating manual/BEAROMOS 2020/Version 1.0
Page 23 of 26
7.2
Repair
Replace sensor housing (black housing part of the sensor, part number: 153125):
1.
Remove the sensor cable
2.
Loosen cover Allen screws and remove sensor cover
3.
Lift off the brush by pulling the black lever of the brush forward and switching it in the
direction of
the sensor housing.
4.
Remove the Allen screws from the sensor housing (x4).
5.
Carefully lift the sensor housing off the supporting tube (make sure that the carbon brushes
are not damaged).
6.
Insert new O-ring seal into supporting tube
7.
Carefully place the new sensor housing on the supporting tube (make sure that the carbon
brushes are not damaged).
8.
Screw the sensor housing to the supporting tube with the 4 Allen screws.
9.
Put the brush in place on the shaft by pulling the black lever of the brush forward and turning
it
in
the direction of the shaft.
10.
Insert new O-ring seal into sensor housing
11.
Attach the cover with the Allen screws in the cover
12.
Connect sensor cable to new sensor housing
8
Packaging
H
180mm
W
220mm
L
280mm
Figure 13: Packaging geometry