Product description
Note:
Ideally, water hardness should be
1-2 GPG or 1-25 ppm (5-7 dH / 8-12 fH)
. Chlorine
content should not exceed
100 mg per liter
. The ideal
pH value is 7
. Local regula-
tions apply.
Water pressure:
Minimum pressure:1 bar
Maximum pressure:3 bar
Note:
We recommend setting the decompression valve to 3 bar.
Feed water temperature:
Min. 50° F / 10 °C
Max. 95° F / 30 °C
3.2.4 Volumes
1 Hot water boiler
0,8 l Hot water
1 Steam boiler
1.2 l of which 0.4 l are steam
2 Coffee grinders
1.8 lbs / 0.75 kg coffee beans per coffee grinder
3.3
Chip card functions
Important!
Chip cards should be handled with the same care as bank cards (do not bend, do not
use as “door openers”, etc.)
3.3.1
Chip card "SAVE DATA PLUS"
The SAVE DATA PLUS chip card is a security card which enables the machine set-
tings to be saved or data from the card to be transferred to the machine.
When a chip card is in the card reader, no products can be selected.
3.3.2
Chip card "CUP"
The "CUP" chip card queries and adds up each individual product counter - no reset
function.
Page 3-6
BASO-1 SUSA - 02.03 - V02