Scarab M65T Operating Instructions
Part No. SCAZ043468 1.6.01
39
E&OE
Removing and Cleaning Water Strainer Elements
Both the low-pressure and, if fitted, the high-pressure water pump
are fitted with strainers to ensure that foreign matter does not enter
the pump. The following steps detail the recommended cleaning
procedure:-
1. Move shut off valve(s)
(
1
)
into the closed position.
2. Move drain valves
(
2
)
into the open position.
3. Unscrew the filter bowl
(
3
)
from the housing
(
4
)
.
4. Remove the element
(
5
)
.
5. Washout the filter bowl.
6. Washout the element with clean water or replace if it is too
contaminated.
7. Before reassembling the unit, apply some grease to the o-ring
(
6
)
to ensure a water tight fit with the filter bowl and housing.
8. Refit the element and filter bowl tighten hand tight.
9. Close drain valves
(
2
)
.
10. Open any closed shut off valves
(
1
)
.
Valves for high pressure pump
Valves for low pressure pump
3
5
4
1
1
2
2
2
1
6