Scarab M65T Operating Instructions
Part No. SCAZ043468 1.6.01
36
E&OE
Hydraulic Oil Tank
The hydraulic oil tank is accessed via the left hand gantry door.
Always wear suitable personnel protective equipment (PPE).
Ensure that the machine is on a flat and level surface with the auxiliary engine stopped for a suitable period, to allow the engine to cool sufficiently.
It is advisable to top up the hydraulic oil level when the system is cold.
The hydraulic oil tank gauge is fitted with a low level sensor which will display and the
‘
Fault Active
’ symbol on the LCD monitor and buzzer will sound and the sweep gear will be
lifted. The operator should then further investigate the problem.
To check and top up the hydraulic oil use the following procedure:
1. Open left hand gantry door.
2. Using the gauge to the side of the sight glass
(
1
)
check the oil level. Ensure you use the
correct part of the gauge depending on if the hopper is raised or lowered.
3. Use the appropriate sized spanner to undo and then remove the filler cap
(
2
)
.
4. Top up to the correct level using Renolin B10 VG 32 or equivalent hydraulic oil.
5. Replace filler cap and tighten bolt.
6. Close the left hand gantry door.
Hydraulic Oil: Fuchs Renolin B10 VG 32
2
3
1
4
Oil Tank Components
(
1
)
Sight glass/gauge.
(
2
)
Oil filler cap.
(
3
)
Return filter.
(
4
)
Suction filter.
Summary of Contents for M65T
Page 52: ...Scarab M65T Operating Instructions Part No SCAZ043468 1 6 01 52 E OE Operator Notes ...
Page 53: ...Scarab M65T Operating Instructions Part No SCAZ043468 1 6 01 53 E OE Operator Notes ...
Page 54: ...Scarab M65T Operating Instructions Part No SCAZ043468 1 6 01 54 E OE Operator Notes ...
Page 55: ...Scarab M65T Operating Instructions Part No SCAZ043468 1 6 01 55 E OE Operator Notes ...
Page 56: ...Scarab M65T Operating Instructions Part No SCAZ043468 1 6 01 56 E OE Operator Notes ...
Page 57: ...Scarab M65T Operating Instructions Part No SCAZ043468 1 6 01 57 E OE Operator Notes ...