5.6.2 Remote control related faults
Symptom
Cause
Correction
A
8
The radio remote control
does not work
The connection was lost
Reinitialise the connection
O
The battery is empty on the remote control
Replace the battery to a charged one
O
The emergency stop button is depressed
Release the emergency stop button
O
The antenna is damaged
Replace the antenna
S
Table 5-2
Common faults – remote control
5.6.3 Transportation related faults
Symptom
Cause
Correction
A
9
Transportation does not
work while offline.
The batteries are empty
Charge the batteries
O
The batteries are damaged
Replace the batteries
S
Transportation does not
work at all.
The drive motors are not connected properly
Connect the motors
Table 5-3
Common faults – transportation
8
See access table ”Table 5-5”
9
See access table ”Table 5-5”
Summary of Contents for Scan Combiflex 700
Page 1: ...SCANMASKIN N Scan Combiflex 700 Users Guide MACHINES MINERALS KNOW HOW http www scanmaskin com...
Page 6: ...Scan Combiflex 700 Manual v Layout Mountingplate 38 7 Warranty 46 8 EU Declaration 47...
Page 7: ...Scan Combiflex 700 Manual vi 9 Alphabetical reference 48 10 Contact information 50...
Page 42: ...Scan Combiflex 700 Manual Chapter 6 36 Grinding head...
Page 44: ...Scan Combiflex 700 Manual Chapter 6 38 Electrical schematics Layout Mountingplate...
Page 45: ...Scan Combiflex 700 Manual Chapter 6 39 Layout Panel...
Page 46: ...Scan Combiflex 700 Manual Chapter 6 40 Connection block...
Page 47: ...Scan Combiflex 700 Manual Chapter 6 41 Inverter...
Page 48: ...Scan Combiflex 700 Manual Chapter 6 42 Control Voltage 24 VDC...
Page 49: ...Scan Combiflex 700 Manual Chapter 6 43 Radio Remote Unit...
Page 50: ...Scan Combiflex 700 Manual Chapter 6 44 Transport Motor Drivesytem TMD...
Page 51: ...Scan Combiflex 700 Manual Chapter 6 45 Control Panel...