MSR120D Programmer’s Manual UDN PM009 Rev. E
Section 5 – Configuration Commands 2005/2/23
Table 5-12. Set Track 1 Suffix Code
Command Form (Hex)
Track 1 Suffix Code
09h 00h 03h 73h 31h 00h 48h
Disable (default)
Example of Track 1 Suffix Code Setting
09h 00h 03h 73h 31h 06h 4Eh
One character: 06h
s2 data (73h 32h data)
-
Set Track 2 Suffix Code
1 Suffix can be set as 1-6 characters
2 If first character = 00h, suffix code of track 2 will not be sent. It means this function is disabling.
Table 5-13. Set Track 2 Suffix Code
Command Form (Hex)
Track 2 Suffix Code
09h 00h 03h 73h 32h 00h 4Bh
Disable (default)
Example of Track 2 Suffix Code Setting
09h 00h 03h 73h 32h 06h 4Dh
One character: 06h
s3 data (73h 33h data)
-
Set Track 3 Suffix Code
1 Suffix can be set as 1-6 characters
2 If first character = 00h, suffix code of track 3 will not be sent. It means this function is disabling.
Table 5-14. Set Track 3 Suffix Code
Command Form (Hex)
Track 3 Suffix Code
09h 00h 03h 73h 33h 00h 4Ah
Disable (default)
Example of Track 3 Suffix Code Setting
09h 00h 03h 73h 33h 06h 4Ch
One character: 06h
K1A type start end (4Bh 31h 41h type start end)
-
Set Transmitting Data Block, Channel A of Track 1
where
type
means card type,
start
means start address of transmitting data, and
end
means end address of
transmitting data.
1 (31H) CA old DMV
2 (32H) AAMVA
3 (33H) ISO
4 (34H) JIS
6 (36h) Trade Show
O (4FH) any type
Table 5-15. Data Block Channel A, Tk1
Command Form (Hex)
Data Block Channel A, Tk1
09h 00h 06h 4Bh 31h 41h 00h 00h 00h 34h
Disable (default)
Page 19
Total 42 pages