MSR120D Programmer’s Manual UDN PM009 Rev. E
Section 5 – Configuration Commands 2005/2/23
SS = START SENTINEL
TRACK1= “%” (ISO, DMV & AAMVA)
TRACK2= “;” (ISO, DMV & AAMVA)
TRACK3= “
;
”
(ISO)
“%”
(AAMVA)
“!”
(CA
old
DMV)
ES = END SENTINEL
TRACK1, 2 & 3= “?” (ISO, CA old DMV & AAMVA)
STX = START TEXT, ETX = END TEXT, DLE = DATA LINK ESCAPE, LRC = CHECKSUM (optional).
When MSR100 output format is disabled, the output data format restores to previous setting.
Note: 1. Only following commands are valid while MSR100 output format is enabled:
BRx, DF0, LCx, RTx, CTx, and BL.
2. If read error or no data, then output nothing.
SN data (53h 4Eh data
)
-
Write serial number
1 Serial number can be set as 0-7 characters
2 The character in hex is valid from 20 to 7E.
Table 5-32. Write serial nuber
Command Form (Hex)
Serial Number Code
09h 00h 02h 53h 4Eh 16h
0000000 (7 zeros, default)
Example of Serial Number Setting
09h 00h 03h 53h 4Eh 0Ah 1Dh
One character: 0Ah
09h 00h 09h 53h 4Eh 31h 32h 33h 34h 35h 36h 37h 2Dh
Seven characters: 31h 32h 33h 34h 35h 36h 37h
Note: Before sending SN command, if the LED is blinking, it may let LED keep either on or off still during the SN
is in the process of writing.
RDx (52h 44h x)
-
Raw Data Output Mode Enable/Disable
x = E (45h enable) or D (44h disable)
Table 5-32. Raw Data Output Mode Setting
Command Form (Hex)
Raw Data Output Mode
09h 00h 03h 52h 44h 44h 58h
Disable (default)
09h 00h 03h 52h 44h 45h 59h
Enable
This command is only effective in self-arm mode and protocol 0. The raw data output mode setting could be
viewed from byte 85 in EEPROM via sending command RE0.
When Raw Data Output mode is enabled, the output data format is as below:
Single Track <01H or 02H or 03H> Prefix <Raw Data>Suffix<CR>
<01H or 02H>Prefix<Raw Data>Suffix<CR>
Dual Track
<02H or 03H>Prefix<Raw Data>Suffix<CR>
<01H>Prefix<Raw Data>Suffix<CR>
<02H>Prefix<Raw Data>Suffix<CR>
Triple Track
<03H>Prefix<Raw Data>Suffix<CR>
Page 25
Total 42 pages