SBS System – SB-1000 Operation
17
Single Point Manual Balance
1) Stop Spindle - This screen requests the operator to stop the spindle. The Stop Spindle icon flashes as a
reminder. This screen stays until the control detects that the spindle rotation has stopped.
2a) Apply Weights,
Zero Phase
- Once the spindle is stopped, this screen shows the operator how to place
the weight. During the Zero Phase the weight should be removed.
2b) Apply Weights,
Test Phase
- The test weight must be added (
+ ) at zero position. The value of the
test weight is shown.
During the Test Phase pressing Manual (note
icon) will
display this screen, allowing the test weight value to be edited.
The weight units can also be selected from g, oz, lb, kg, and
nothing.
It is essential to enter an accurate value for the test weight.
When done editing press to save changes and return to the
Apply Weights screen above.
2c) Apply Weights,
Solution Phase
- The weight should be changed to the position and mass shown to bring
the balance to a minimum.
Weight change display can be either additive (
+
) or absolute (
= )
. Press Manual button to
toggle between these options (note
icon). This selection will remain active until changed. Additive
weight display (
+
) shows what incremental changes should be made to achieve balance, with all
previously placed weights on the grinder remaining in place. Absolute weight display (
= )
shows what
total weight should be applied to achieve balance, assuming all previously placed weights will be removed.
Additive Weight Change
Absolute Weight Change