![SBS SB-1000 Operation Manual Download Page 35](http://html.mh-extra.com/html/sbs/sb-1000/sb-1000_operation-manual_1205336035.webp)
SBS System – SB-1000 Operation
29
Error Indications
The
screen icon is displayed when the error can be hidden manually by pressing the
button.
The Error screen icon blinks for emphasis on these error screens.
Error
Code
Message
Description
A
Checked continuously.
Clears automatically.
RPM signal present but out of operating range
(300 to 30000).
B
Checked continuously.
Clears automatically.
Vibration
sensor is
open
, unplugged, or faulty.
C
Checked continuously.
Clears automatically.
Vibration
sensor is
shorted
or faulty.
D
Checked at the end of Automatic mode balance
weight motion.
Clears automatically.
Balancer
motor and/or cable has a
short
circuit.
E
Checked at the end of Automatic mode balance
weight motion.
Clears manually.
Balancer
motor and/or cable is
open
or
unplugged.
F
Checked at the end of Automatic mode balance
weight motion.
Clears manually.
Balancer motor
excess current
.
G
Checked at power-up.
Checksum Error.
Recommend flash update.
H
Checked continuously.
Low +15V supply to RPM sensor and CNC
connector.
Check sensor and/or cable for short circuit.
Check CNC connections for short circuit.
I
Automatic Balance cycle failed to reach limit.
Cleared manually.
Try higher Limit.
Balancer may be incorrectly sized.
J
Checked during a balance cycle.
Clears automatically.
RPM signal is missing.
Spindle may not be turning.
Balancer and/or cable may be unplugged or
faulty.