Document
9911004rev27
Title
Date
2017-02-16
Page
64(81)
SBS MicroSMART Battery Charger Technical Handbook
The remote input function can be set to a state called
Start/Stop
where charging only can
occur when remote input is activated i.e. connected to battery minus. This function makes it
possible to activate and deactivate charging simply by connect respectively disconnect the
charger from the battery. Here follows a tutorial for how this function can be activated.
1.
While in the service menu put the marker on
I/O control
and press
OK
. The following
menu is shown.
2.
Select
Remote input
and press
OK.
3.
Put the marker on the field
Function
and press
OK
. If necessary, enter the level 1 pin-
code and select
Start/Stop.
See the tutorial
Edit parameters
for more information.
4.
Press
ESC
until the main menu is shown. Note that charging now only can be carried
out when remote input is connected to battery minus. If the battery is disconnected
from the charger during ongoing charge the following message will appear and one of
the status indicators will be flashing yellow. Note that charging is terminated within
approximately 20 ms from the point when the charger and battery are disconnected
from each other. Charging can be resumed by connecting the charger to the battery
again.