Document
9911004rev27
Title
Date
2017-02-16
Page
14(81)
SBS MicroSMART Battery Charger Technical Handbook
When configured as CAN controlled
BMS ctrl
or
Slave
the main screen text will be different.
Please refer to section CAN.
5.3.1.
Battery status
The battery status menu is visible when a BMU is connected to the charger and shows
information about the connected BMU. The information is updated once every minute during
charging.
B-ID
Battery numeric identifier, configured in BMU.
Tag
Battery alphanumeric identifier, configured in BMU.
SOC
Current battery state of charge calculated by the BMU.
Battery temp
Battery temperature measured by the BMU.
5.3.2.
Charging status
The charging status menu is shown when a battery is connected to the charger. Charging
status shows information about the ongoing battery charge.
Start date
Date when the battery was connected to the charger.
Start time
Time when the battery was connected to the charger.
Start VPC
Actual battery voltage per cell when the battery was connected to
the charger. Measured before start of charge.
End VPC
Actual battery voltage per cell when the charging main stage was
completed. Measured prior to main charge end. This value will
show N/A until the main stage is completed.
If the battery is disconnected prior to completion of the main stage
End VPC
will be the battery voltage per cell 5 seconds before the
battery was disconnected.
Charged Ah
Charged Ah since battery connected to the charger.
Charged Ah (%)
Charged Ah in main stage in percent of configured battery
Capacity
. For a cycle log to be stored this value must be greater