Saia-Burgess Controls AG
Manual for PCD2|3.W7x0
│ Document 26-
833 E
NG07 │ 2018-10-18
2
Programming
2-4
Overview
WM_Weigh
Weighing and zeroing the scale are controlled by the FBox WM_Weigh. This Box
always returns a result, whether or not the scale has already reached the final
weight. The Status Box is used to determine the status of the scale. If a “1” ap
-
pears at the “Still” output, the user can be sure that the scale has reached a stable
final state. All inputs react to a transition from “0” to “1”.
Weigh
Triggers the readout of a weight.
Dweigh
Triggers the readout of a differential weight.
Zero
Resets the scale to zero (tare).
Weight
Outputs the weight in the scaled unit.
Dweight
Outputs the differential weight in units per second. Please note that the
additional smoothing filter delays the output.